Dri-Eaz DrizAir 1200 Kullanıcı El Kitabı - Sayfa 4

Nem Alıcı Dri-Eaz DrizAir 1200 için çevrimiçi göz atın veya pdf Kullanıcı El Kitabı indirin. Dri-Eaz DrizAir 1200 5 sayfaları. 110v/50hz portable dehumidifier
Ayrıca Dri-Eaz DrizAir 1200 için: Kullanıcı El Kitabı (13 sayfalar), Kullanıcı El Kitabı (18 sayfalar), Kullanıcı El Kitabı (4 sayfalar), Kullanıcı El Kitabı (2 sayfalar), Kullanıcı El Kitabı (19 sayfalar)

Dri-Eaz DrizAir 1200 Kullanıcı El Kitabı
ER 1,2,3,5,6
Problem with electronic control panel. Contact CROWN RENTAL
ER 4 Check the temperature or sensor cable, contact CROWN RENTAL for
instructions
ER 8 Check the touchpad key. Press and release each key several times.
ER 9 Check for obstructions or kinks in the drain hose.
WARNING

ELECTRIC SHOCK HAZARD

Unplug any DrizAir dehumidifier before performing maintenance.
Never use a water hose or pressure washer to clean coils; water could enter the
electrical compartment causing a shock hazard. Follow cleaning instructions in
manual.
PURGE. Press the PURGE key to empty water from the pump reservoir. During normal
operation, the pump purges automatically every six minutes, or whenever the
reservoir is full. The display will read PUMP PURGING with a numeral countdown.
To purge the pump manually:
1) Turn the power off using the OFF key, and let the unit sit plugged in for
about 10 minutes. This allows water to drip from the coils.
2) Press PURGE to remove residual water.
• Check coils, and clean when visibly dirty. Dirty coils can cause the unit to
overheat.
1. Unplug unit
2. Remove housing, locate coils and allow coils to dry if wet.
3. Vacuum both sides of the coils until clean, being careful not to let the
nozzle touch the fins; as that may cause damage by bending them.
• Check catch basin tray, and clean when dirt and debris are present.
1. Wipe clean with a rag.
• Check drain hose.
1. Look for obstructions. Disconnect and clear any debris present.
2. Reattach gravity drain hose.
MODEL DRIZAIR 1200, F203 CONTROLS TOUCHPAD
TYPE STANDARD REFRIGERANT HOUR METER YES
HEIGHT 32" (83 CM) WATER PUMP-OUT CENTRIFUGAL
WIDTH 20" (50 CM) DRAIN HOSE LENGTH 40 FT (12.2 M)
DEPTH 19.5" (50 CM) AIR FILTER 3M™ HIGH AIRFLOW*
USE WEIGHT 80 LB (36 KG) WHEELS SEMI-PNEUMATIC
WATER REMOVAL MAX 123 PT/DAY (58 L) HANDLE TELESCOPING
WATER REMOVAL AHAM 64 PT/DAY (30 L) HOUSING ROTOMOLDED
OPERATING RANGE 33° - 100° F (1° - 38° C) POWER 115V 6.4 AMPS
COMPRESSOR TYPE 6,670 BTU ROTARY CORD LENGTH 25 FT (7.6 M)
DEFROST TYPE HOT-GAS BYPASS SAFETY MARKS UL, C-UL
PROCESS AIR 227 CFM (386 CMH)
TROUBLESHOOTING
For any problems not listed below, CALL CROWN RENTAL
Unit does not operate
1. No power to machine - Plug in the unit; check power at outlet.
2. Switch not turned on - Turn on switch.
3. Compressor will not start Unit needs 5 minutes before restart
Overload preventing start up - Switch off unit, wait 5 minutes before starting.
Reduce room temperature below 90°F (32°C).
3. Blower wheel not turning Obstructed blower - Loosen blower wheel set screw
Remove obstruction. Tighten Screw.