Installation

INSTALLING THE DUCTWORK

CAUTION
To reduce the risk of fire, use only metal ductwork.
1 Decide where the ductwork will run between the hood and the outside. Figure 5.
2 A straight, short duct run will allow the hood to perform most efficiently.
3 Long duct runs, elbows, and transitions will reduce the performance of the hood. Use
as few of them as possible. Larger ducting may be required for best performance
with longer duct runs.
4 Install a roof or wall cap. Connect round metal ductwork to cap and work back
towards hood location. Use duct tape to seal the joints between ductwork
sections.
ROOF CAP
8"
ROUND
DUCT
DECORATIVE
FLUE
8"
ROUND
HOOD
ELBOW
24" to 30" ABOVE COOKING
SURFACE (See "Install Mounting
Bracket" section for mounting
restrictions).
Figure 5
EAVE
VENT