4. As with any water purifier installation, routine maintenance is necessary to insure your equipment is operating correctly.
Regular inspection must also include the inspection of the ground to insure grounding wires are secure to both the water
purifier and grounding point as originally installed. Regular inspection must also include confirmation that approved ground
fault circuit interrupt (GFCI) receptacle is still operational and that water purifier is plugged into this GFCI. Any components
which are damaged, or broken should be replaced.
L
I
AMP
NSTALLATION OR
.10-0508B
USING BALLAST NO
Figure 7 - Lamp Replacement
Step 2 - Remove End-Cap
SAFETY EQUIPMENT REQUIRED TO PERFORM TASK
1.
WARNING: Disconnect power to water purifier, and remove ground connector from the chamber.
TM
2. Remove EASY-OFF
3. Pull lamp cord and carefully withdraw lamp approximately 2 inches from chamber. While holding lamp end, remove lamp
socket from exposed lamp end.
4. Carefully withdraw lamp from chamber. Be sure to withdraw lamp straight out without angling until completely
clear of quartz sleeve.
CAUTION: Lamp and quartz sleeve are easily damaged. Exercise care when handling.
5. Reinstall lamp in reverse order.
WARNING: Germicidal ultraviolet rays are harmful to eyes and skin. Do not restore power to water purifier until
lamp and both EASY-OFF
R
MIN-6
EPLACEMENT
Step 3 - Remove Socket
end cap by pulling cap off static gland nut.
TM
end caps have been properly reinstalled.
MIN-9 120
50/60H
AND
V
Z
Step 1 - Disconnect Power to Water
Purifier and Remove Ground Connector
Step 4 - Remove Lamp
13