Atlantic Ultraviolet 10-0508B Kullanıcı El Kitabı - Sayfa 9
Su Filtrasyon Sistemleri Atlantic Ultraviolet 10-0508B için çevrimiçi göz atın veya pdf Kullanıcı El Kitabı indirin. Atlantic Ultraviolet 10-0508B 16 sayfaları. Germicidal ultraviolet water purifiers
Ayrıca Atlantic Ultraviolet 10-0508B için: Kullanıcı El Kitabı (20 sayfalar)
MAINTENANCE
The water purifier is designed to operate with a minimal amount of maintenance, providing the water quality does not exceed
maximum concentration levels, see "Water Quality" in the "Product Application" section. Ordinary maintenance consists of;
•
Lamp replacement is recommended every 10,000 hours of operation, approximately 12 months of continuous service.
•
Cleaning of the quartz sleeve, when conditions warrant. It is recommended that the inspection of quartz sleeve be performed
after one month of use. If quartz sleeve is found to be coated (not clear), then frequency of cleaning must be done more often.
Deposits or discoloration on the surface of quartz sleeve are caused by excessive levels of the subject contaminant within
the water that is in contact with the quartz sleeve. Most deposits on the quartz sleeve are caused by an excess of calcium
(hardness), iron or manganese. Table 1 on Page 4 lists the maximum recommended concentration of these minerals in the
water that passes through the germicidal ultraviolet purifier. If you encounter difficulty due to deposits on the quartz sleeve,
your dealer will be able to recommend suitable pretreatment to reduce or eliminate the offending contaminant. If quartz sleeve
is clean (clear) then frequency of cleaning may be extended.
•
Always disconnect the water supply and completely drain the water purifier if it will be subjected to temperatures
below freezing.
•
Contact factory with questions.
Inspection
1. Regularly inspect the water purifier to ensure that the germicidal lamp is still in operation.
•
An LED indicator light, located on the ballast, and EASY-OFF
indication of germicidal ultraviolet lamp operation, but do not indicate the level of ultraviolet intensity or transmission
through the water.
•
Ballast has a built-in audio alarm which will indicate lamp failure.
On purifiers so equipped, the SENTRY
•
2. To ensure proper operation of the water purifier, regular biological testing of the purifier outlet water should be performed on a
schedule recommended by local public health authorities, or at minimum; at installation, quarterly for the first year of service
and annually, at lamp replacement, for the life of the water purifier.
3. Additional testing should be performed whenever modifications, change or additions are made to plumbing system, pumps,
well source water etc. to ensure adequate disinfection under new condition.
4. As with any water purifier installation, routine maintenance is necessary to ensure your equipment is operating correctly.
Regular inspection must also include the inspection of the ground to ensure grounding wires are secure to both the water
purifier and grounding point as originally installed. Regular inspection must also include confirmation that approved ground
fault circuit interrupt (GFCI) receptacle is still operational and that water purifier is plugged into this GFCI. Any components
which are damaged, or broken should be replaced.
Quartz Breakage
Broken Quartz is SHARP. It is recommended that Protective Glasses or Face Shield and Gloves be worn.
Wear protective gloves when handling broken germicidal ultraviolet lamps and/or quartz sleeves. In the event of
breakage, DO NOT use a household vacuum cleaner to pick up fragments of quartz. Sweep up debris into a plastic
bag and dispose of properly
Safety Sensor provides visual indication of ballast and ultraviolet lamp operation
TM
.
End Cap with Clear Window Plug provide visual
TM
9