Atlantic Ultraviolet Sanidyne Kurulum Operasyon ve Bakım - Sayfa 10

Aksesuarlar Atlantic Ultraviolet Sanidyne için çevrimiçi göz atın veya pdf Kurulum Operasyon ve Bakım indirin. Atlantic Ultraviolet Sanidyne 16 sayfaları. Portable area sanitizer
Ayrıca Atlantic Ultraviolet Sanidyne için: Kullanıcı Kılavuzu (12 sayfalar)

TROUBLE SHOOTING

warning
: Always disconnect power to the unit before performing any service or maintenance.
Wear personal protection equipment; Gloves, long sleeve shirt with no gaps between cuffs and gloves
and an ultraviolet blocking face shield MuSt be worn to cover and protect eyes and all exposed skin.
iMPortant: This unit is to be serviced ONLY by qualified and factory authorized personnel.
Problem
Sanidyne
not
®
operating . . .
Lamp not operating . . .
Sanidyne
fails to
®
shut off . . .
f
r
use
ePlaCement
The fuse is contained in a small plastic tray at the bottom of the power connector.
Remove the power connector from the back of the Sanidyne
1.
by inserting the blade in one of the horizontal slots and gently twisting the handle to bring the tray forward.
2. A spare fuse is accessible, clipped in front of the active fuse.
Step 1 - Insert Screwdriver & Bring
Table 1 - Troubleshooting
Possible cause
Power disconnected...
Fuse . . .
Germicidal lamp fault...
Germicidal lamp not
properly seated...
Loose Connection...
Ballast
Timer assembly faulty...
tray forward
corrective action
Check connections.
Remove power connector to check and replace fuse
if necessary.
Swap suspect lamp, with lamp known to be good. If
suspect lamp does not operate, replace lamp.
Check lamp socket and re-install lamp if necessary.
Inspect for loose or disconnected wires.
Disconnect the fixture from utility power.
Then replace ballast
Wearing protective clothing and face shield, enter
area, and disconnect power to unit. Call factory for
technical service.
. A screwdriver can be used to access the fuse
®
Step 2 - open tray
(Spare Fuse is Clipped in Front of the Active Fuse)
10