Double insulated tools may be used in
either of the 120 volt outlets shown in the
preceding illustration. (See Outlets for
2-Prong Plug.)

Extension cords

1.
Grounded
tools require a three wire
extension cord. Double Insulated
tools can use either a two or three wire
extension cord.
2.
As the distance from the supply outlet
increases, you must use a heavier gauge
extension cord. Using extension cords
with inadequately sized wire causes a
serious drop in voltage, resulting in loss
of power and possible tool damage.
(See table A.)
3.
The smaller the gauge number of the
wire, the greater the capacity of the cord.
For example, a 14 gauge cord can carry
a higher current than a 16 gauge cord.
(See table A.)
4.
When using more than one extension
cord to make up the total length, make
sure each cord contains at least the
minimum wire size required. (See table
A.)
5.
If you are using one extension cord for
more than one tool, add the nameplate
amperes and use the sum to determine
the required minimum cord size. (See
table A.)
6.
If you are using an extension cord
outdoors, make sure it is marked with the
suffix "W-A" ("W" in Canada) to indicate it
is acceptable for outdoor use.
7.
Make sure the extension cord is properly
wired and in good electrical condition.
Always replace a damaged extension
cord or have it repaired by a qualified
electrician before using it.
REV 10d
SKU 46055
For technical questions, please call 1-800-444-3353.
8.
Protect the extension cords from sharp
objects, excessive heat, and damp or
wet areas.
REcOMMEnDED MInIMuM WIRE GAuGE
FOR EXtEnSIOn cORDS*
nAMEPLAtE
AMPERES
(at full load)
25'
0 – 2.0
2.1 – 3.4
3.5 – 5.0
5.1 – 7.0
7.1 – 12.0
12.1 – 16.0
16.1 – 20.0
tABLE A
Symbology
Double Insulated
Canadian Standards Association
Underwriters Laboratories, Inc.
V~
Volts Alternating Current
A
Amperes
tPI
Teeth Per Inch
No Load Revolutions per Minute
n 0 xxxx/min.
(RPM)
(120/240 VOLt)
EXtEnSIOn cORD
LEnGth
50'
75' 100' 150'
18
18
18
18
18
18
18
16
18
18
16
14
18
16
14
12
18
14
12
10
-
14
12
10
-
-
12
10
* Based on limiting the line volt-
age drop to five volts at 150% of
the rated amperes.
Page 7
16
14
12
12
-
-
-