Absen KL2.5 Kullanıcı Kılavuzu - Sayfa 16
Dijital Tabela Absen KL2.5 için çevrimiçi göz atın veya pdf Kullanıcı Kılavuzu indirin. Absen KL2.5 20 sayfaları.
4.2 Power cable wiring
KL series cabinets adopts 3×1.5mm² power line to connect distribution box or socket with the
power connector in the cabinet.
Maximum
power
Type
consumption
KL1.2
582W/m2
KL1.5
555W/m2
KL1.8
540W/m2
KL2
480W/m2
KL2.5
540W/m2
KL3
540W/m2
KL3.9
360W/m2
4.3 Network cable wiring
For signal line wiring, please calculate the resolution ratio according to the pixel points of each
cabinet. Note that the maximum belt load of a single net port does not exceed 65W pixel points,
and the overall belt load does not exceed the belt load limit of the sending box.
16
Maximum recommended load for single main
power line
110V
4
5
5
6
5
5
8
KL Series Product
220V
9
10
10
12
10
10
16
User Manual