15.4 To adjust the contrast of the LCD
All field wiring and components must be installed by an
1 Display the Contrast adjustment settings screen (15.4) (Refer to
installer and must comply with the applicable legislation.
"20. Main menu structure"
and "Appendix").
2 Use
to change the contrast.
NOTICE
When the remote controller thermo function is used, select
Contrast Adjustment
the installation location considering it should be a place:
where the average temperature in the room can be
Dark
that is not exposed to direct sunlight,
Light
that is not near a heat source,
that is not affected by outside air or air draught due to
Return
Setting
3 Push
to confirm the setting.
where the display is kept clean.
where the front is kept clear.
16. Current settings
where the temperature is between –10°C and 50°C.
where the relative humidity is max. 95%.
1 Display the Setting status list screen (16) (Refer to
"20. Main menu
structure"
and "Appendix").
NOTICE
2 A list of the current setting status is displayed.
Do NOT install the remote controller:
Near machinery emitting electromagnetic radiation.
3 Push
to return to the Main Menu.
17. Clock & calendar
In moist areas or places where it may be exposed to
17.1 To set the date & time
1 Display the Date & Time settings screen (17.1) (Refer to
"20. Main
menu structure"
and "Appendix").
2 Use
to select and
to set Year, Month, Day, and time.
After finishing installation:
conduct a trial operation to check for faults,
explain the customer how to operate the remote controller,
Date & Time
using the
Year
2011
ask the customer to store the quick reference for future
Month 01
Day
01
reference.
Thursday
12:00
WARNING
Consult your local dealer regarding relocation and
Return
Setting
reinstallation of the remote controller.
3 Push
to display the confirmation screen.
2.
What is in the box
4 Use
to select Yes and push
.
17.2 To set the hour format (12/24 hours)
1 Display the 12H/24H Clock settings screen (17.2) (Refer to
"20. Main menu structure"
and "Appendix").
2 Use
to select 12H or 24H.
3 Push
to display the confirmation screen.
4 Use
to select Yes and push
.
18. Language
1 Remote controller
2 Wood screws+wall plugs
1 Display the Language screen (18) (Refer to
"20. Main menu
3 Small screws
structure"
and "Appendix").
4 Clamp
5 Quick reference
2 Use
to select the language.
6 Wiring retainer
3 Push
to confirm the setting. Basic screen is displayed.
3.
Remove the upper part of remote
19. Error code display
controller
1 If an error occurs, Error: Push Menu Button or Warning: Push Menu Button
will blink in the basic screen.
Cool
1
Set to
Cool
NOTICE
The PCB is mounted in the upper part of the remote
Return
Error : Press Menu Button
Setting
controller. Be careful not to damage the board with the slot
screwdriver.
2 Push
. The error code will blink and the Contact Info and
model info will be displayed.
4.
Fasten the remote controller
20. Main menu structure
See "Appendix".
INSTALLATION
1
For more information refer to the detailed Installation Manual
.
1
1.
General safety precautions
1 for exposed mounting, fasten with the 2 included wood
screws (Ø3.5x32) and plugs.
Carefully read these instructions before installation. They
2 for flush-mounting, fasten with the 2 included machine
will tell you how to install, how to configure and how to use
screws (M4x16).
the unit properly. Keep this manual in a handy place for
future reference.
For the field supplied switch box, use optional accessory KJB111A
or KJB211A.
This is an option to be used in combination with Daikin
units. Refer to the installation and operation manual of the
INFORMATION
units for installation and operation instructions.
Put on a flat surface. Be careful not to distort the shape of
the back plate of the remote controller by overtightening the
Please read these
"1. General safety precautions"
carefully before
mounting screws.
installing the remote controller.
Improper installation or attachment of equipment or accessories
could result in electric shock, short-circuit, leaks, fire or other
damage to the equipment or personal injury.
If unsure of installation procedures or use, always contact your
dealer for advice and information.
Do NOT install the remote controller by yourself. Improper
installation may result in electric shocks or fire. Consult your Daikin
dealer.
1.
The detailed installation manual and operation
manual is available on http://
www.daikineurope.com/support-and-manuals/
product-information/.
BRC1E52A7
4PW71247-1-KAD – 2014.02
5.
Wire the indoor unit
4 methods:
1 from the rear,
2 from the left,
3 from the top,
4 from the top center.
detected,
1
e.g. door opening/closing,
PCB
1x
Electromagnetic radiation may disturb the operation
of the control system and result in a malfunction of the
3
unit.
water. If water enters the remote controller, electric
2
shocks may be caused and the inner electronics may
fail.
Operation
part of this Quick Reference,
PCB
1x
3
1
2
3
4
5
6
1x
2x
2x
1x
11x
1x
3
3
+
PCB
1x
3
Insert a slot screwdriver into the slots (1)
in the lower part of the remote controller
(2 places), and remove the upper part of
3
the remote controller.
4
PCB
1x
3
1 indoor unit
2 notch the part for the wiring to pass through with nippers,
2
etc.
2
3 secure the wiring to the uppercase using the wiring
retainer and clamp.
Connect the terminals on the remote controller (P1, P2), and the
terminals of the indoor unit (P1, P2). (P1 and P2 do not have
polarity.)
INFORMATION
When wiring, run the wiring away from the power supply
wiring in order to avoid receiving electric noise (external
noise).
Wiring specifications
Wiring
type
Sheathed
vinyl cord
or cable
INFORMATION
1. Peel the sheat for the part that has to pass through the
inside of the remote controller case (L). Refer to the
figure and the table below. It is important to keep
double isolation up through the notch of the remote
controller case.
2. For easy wiring, it's better to keep ±10 mm difference
between the length of the 2 wires.
P1 P2
1
Wiring outlet
Top outlet
Top center outlet
6.
Reattach the upper part of the remote
controller
NOTICE
Be careful not to pinch the wiring when attaching.
2
Align the upper case with the tabs of the
lower case (6 points), insert and install
the upper case.
P1 P2
First begin fitting from the clips at the
1
bottom.
NOTICE
1. The switch box and wiring for connection are not
included.
2. Do not directly touch the PCB with your hand.
7.
Power on
2
1 Put on the power.
2 Checking the connection. Please stand by. is displayed.
3 After a few seconds, the basic screen is displayed.
2
If controlling 1 indoor unit or 1 group of indoor units with 2
remote controllers
P1 P2
1
1 Put on the power for both remote controllers.
2 Determine which one is the sub/main remote controller.
3 When Error code:U5 - Checking the connection. Please stand by. is
displayed on both remote controllers, push and hold the
button of the sub remote controller for 4 seconds.
4 The sub remote controller now displays Sub RC.
INFORMATION
The main remote controller still displays Main RC.
5 After a few seconds, the basic screen is displayed.
Refer to the detailed Installation Manual
installation instructions concerning:
Field settings,
2
Test operation method (in case of SkyAir),
Checking procedure of Error History,
Registration method of the Maintenance Contact,
P1 P2
Confirmation of registered details,
1
Clock & Calendar (see also
"17. Clock & calendar" on page
Language (see also
"18. Language" on page
Prohibit button,
Function Prohibition.
MAINTENANCE
1.
General safety precautions
Wipe the LCD and other surface parts of the remote controller with
a dry cloth when they become dirty.
If the dirt on the surface can not be removed, soak the cloth in
neutral detergent diluted with water, squeeze the cloth tightly, and
clean the surface. Wipe the surface with a dry cloth then.
WARNING
Do not use any paint thinner, organic solvent, or strong
acid.
WARNING
Do not wash the remote controller. Doing so may cause
electric leakage and result in electric shocks or fire.
WARNING
Be sure to stop the operation of the air conditioner and turn
off the power supply breaker at the time of maintenance.
Failure to do so may result in electric shocks or injury.
2.
Filter sign resetting
1 When one of the following messages (Time to clean filter, Time to
Total
clean filter and element, or Time to clean element) appears on the
Size
length
bottom of the basic screen, the filter has to be cleaned.
2 After the filter or element is washed, cleaned, or replaced, push
2
0.75–1.25 mm
≤500 m
to enter the Main Menu.
3 Use
to select Reset Filter Indicator and push
reset the filter sign.
APPENDIX
Cool
Set to
Cool
Return
Setting
L
±150 mm
Main Menu
±200 mm
Air Flow Direction
(8)
(9)
Quick Start
Ventilation
Energy Saving Options
Schedule
Filter Auto Clean
Maintenance Information
(10)
Configuration
Current Settings
Clock & Calendar
Language
(11)
(12)
(13)
(14)
(15)
1
for more detailed
2),
(16)
2),
(17)
(18)
to
Air Flow Direction
Ventilation
Ventilation rate
Ventilation mode
Energy Saving Options
Energy Saving List
Setpoint Range Limitation
Setback Condition
Sensing Sensor (low)
Sensing Sensor (stop)
Setpoint Auto Reset
Off Timer
Electricity Consumption
Schedule
Enable/Disable (12.1)
Schedule nr set (12.2)
Holidays (12.3)
Settings (12.4)
Filter auto clean
Maintenance Information
Configuration
Draft prevention (15.1)
Display
Display
Contrast adjustment (15.4)
Display Mode (15.2)
Display Item (15.3)
Current Settings
Clock & Calendar
Date & Time (17.1)
12H/24H Clock (17.2)
Language
Quick Reference
2