DROPSA VIP4Air Series Kullanım ve Bakım Kılavuzu - Sayfa 6

Yağlama sistemleri DROPSA VIP4Air Series için çevrimiçi göz atın veya pdf Kullanım ve Bakım Kılavuzu indirin. DROPSA VIP4Air Series 16 sayfaları. Minimal air/oil lubrication system
Ayrıca DROPSA VIP4Air Series için: Kullanım ve Bakım Kılavuzu (13 sayfalar)

5. TECHNICAL SPECIFICATIONS
CHARACTERISTIC
Air supply pressure
Working temperature
Working humidity
Permitted lubricants
Oil viscosity at working
temperature
Conservation temperature
SAMBA LEVEL
Temperature:
Maximum switching power:
Maximum current:
Maximum voltage:
WARNING: DO NOT supply the machine with voltages or pressures other than those indicated
on the specification plate.

6. HANDLING AND TRANSPORT

Prior to dispatch VIP4Tools lubrication panels are carefully packed in a cardboard carton. During
transportation and storage maintain the equipment the right way up as indicated on the carton.
On receipt, check that the packaging is not damaged and store the equipment in a dry place.
7. PRECAUTIONS IN USE
It is necessary to carefully read the warnings and the risks involved in using the lubrication panel. The
operator must understand the functioning of the unit by studying the user's manual.
Electric currents
No intervention must be attempted on the equipment without first having disconnected the electrical
power supply (electric level) and ensuring that it cannot be reconnected during the intervention.
All installed equipment, electrical, electronic, tank and base structure, must be connected to the
ground line. (see paragraph 10.7).
Flammability
The oil employed in the lubrication circuit is not normally flammable. It is nonetheless indispensable to
take every precaution against the oil coming into contact with very hot parts or open flames.
Pressure
Prior to any intervention on the equipment ensure that pressure is released from all branches of the
lubrication circuit. Failure to do this could result in oil being discharged under pressure where
connections or components are disassembled (see paragraph 10.6).
Noise
The VIP4Tools lubrication panel does not emit excessive noise, remaining below 70dB(A).
WARNING: before carrying out the replacement of the mini-pumps, empty the tank of
lubricant.
VIP4Tools lubrication panel
5 - 8 bar
-5 - +55 °C
90% max
Mineral - synthetic
32 - 320 cSt
-20 - +65 °C
-10°C - +80°C
50W 5V
1 A
220 V ac
4