Ankhmaway iB001N Kullanıcı Kılavuzu - Sayfa 12
Güvenlik Sistemi Ankhmaway iB001N için çevrimiçi göz atın veya pdf Kullanıcı Kılavuzu indirin. Ankhmaway iB001N 15 sayfaları. With eddystone support
Ankhmaway Beacon
SIMPLIFY YOUR LIFE
Service 0x1802
Characteristic
Property
0x2A06
Read/Write
Note: When put in value 0x01 to this port, it buzzing.
Characteristic
Property
0x2A19
Read/Notify
Note: Read the battery level
Service 0xFF50
Characteristic
Property
0x2A60
Read/Write
Note: The service is used to configure the lock time when the user input the wrong
password for 10 times. Can be configured: 0 x01-0 x14. The unit of the lock time is half
an hour that is 30 minutes to 10 hours.
Service 0xFF40
Characteristic
Property
0x2A50
Read/Write
Note: The service is used to configure the way to add data of the Beacon battery. The
following details:
0x01: Add the battery information at the end of the broadcast data. User can obtain it by
scanning.
0x02: Using the highest two Minor values to show the battery, and divide it into 15 levels.
0x03: Using the highest two Minor values to show the battery.
Value Length
Function
1 Byte
Call Beacon
Value Length
Function
1 Byte
Battery Level
.
Value Length
Function
Configure
1 Byte
Value Length
Configure the type of
1 Byte
lock time
Function
get battery level
User Guide V1.2
Write example
0x01
Read Value
0x64(100%)
Write example
0x01
Write example
0x01