ELEKTRA VCDR Manuel - Sayfa 4
Kablolar ve konektörler ELEKTRA VCDR için çevrimiçi göz atın veya pdf Manuel indirin. ELEKTRA VCDR 20 sayfaları. Heating cables protection of gutters, downpipes and roofs against snow and ice

www.elektra.eu
I
Installation in gutters
and downpipes
First Steps:
•
Measure the lengths of gutters and downpipes
•
Determine the unit heating power
•
Select appropriate cable length according to Table 1
When calculating the heating cable lengths take the following
into consideration:
•
If the calculated heating cable length does not have an exact
equivalent specified in Table 1, you can select a longer heating cable
and place the additional section in the gutter
•
You can select two heating sets, one set for the gutter and a separate
set for the downpipe
•
If the water from downpipes is drained directly into the sewage
system, then the section of the drainage pipe from ground level
to the frost penetration depth must be heated
4