Druck InstruMetrics ADTS542F Güvenlik ve Kurulum Kılavuzu - Sayfa 10

Test Ekipmanları Druck InstruMetrics ADTS542F için çevrimiçi göz atın veya pdf Güvenlik ve Kurulum Kılavuzu indirin. Druck InstruMetrics ADTS542F 16 sayfaları. Air data test set

The test set status indications are as follows:
Test Set Status Indications (4):
Power on and self test:
Off (Power Off)
Standby (Yellow)
4a
Self test in Progress (flashing Green)
Pass/Ready (Green)
Fault (Red)
Battery pack status (if fitted - ADTS542F only):
For LED indications, see User Manual K0553 "ADTS542F Battery Pack"
4b
Note: Battery pack is currently not a purchasable option.
Bluetooth® wireless technology connection status:
Wireless connection present (Blue)
Wired connection and Bluetooth® option enabled (Flashing blue)
Fast flash - enabled and visible for pairing (available for 5 minutes after power-up)*
Slow blink - enabled but not visible for pairing*
Bluetooth® option disabled (Wireless LED off)
4c
Initialization fault (Red) *
* Only applicable to base unit software variant DK0467
Note: The "fast flash" state also occurs when switching the ON/standby switch from
standby to ON. If the Bluetooth® link drops during use then "fast flash" will resume. This
occasionally requires the unit to be returned to standby mode before the link can be re-
established.
Aircraft status:
When the ADTS is controlling the aircraft and it is "off ground", the LED will be Yellow.
When the ADTS is controlling the aircraft to "going to ground", the LED will flash
4d
Yellow.
When the ADTS has made the aircraft "safe at ground", the LED is Green.
In standby-mode, this LED will be off.
If the self test fails, or for any other reason the test set is considered to be unserviceable,
contact Druck and return the test set to the Druck or Druck approved service center.
Copyright 2014 Baker Hughes Company.
8 | ADTS Safety and Installation Guide–English
4a
4b
Figure 7: Test Set Status Indications
4c
4d