Cleaning the filters
Although the Dry-Matic is designed to run continuously for
years, the filters do need cleaning every 8 months or so for
optimal performance (clean at least yearly).
If the filter timer is activated, the hall controller display will start
flashing
Dirty Filter
The white filter bag can be machine washed on gentle cycle
or hand washed - vacuum first to remove excess dust.
Alternatively replace with a new one.
The carbon filter inside the filter box should be replaced every
year.
You may prefer to get a professional to climb into the attic
space to access the filters.
To reset flashing display 'Dirty Filter'
After factory reset or filter timer activated, go to
(c2. over page), follow instructions to select
Optional Heater
Dry-Matic units have been fitted with a thermostatically controlled duct
Some
heater that tempers the incoming air when it is cold in the attic.
Optional Summer Vent Kit
The Dry-Matic Summer Ventilation Kit is an optional add-on for Digital
Dry-Matics.
r time ventilation when it is hot in the ceiling by providing a DM controller
x double the airflow of DM in heat recovery mode) and drives a motorised
ation when it is hot in the ceiling by providing a DM controller
It can be added during installation or several years after installation.
ugh the soffit from outside.
airflow of DM in heat recovery mode) and drives a motorised
from outside.
The digital hall controller can be commissioned to control the motorised diverting
769M
branch damper, directing air intake from the cooler outside air for summer
1
69M
1
months.
C
2
Vent switch typically mounted be-
C
Again, the air intake filter, and the inline 'Sock' will need cleaning as above.
Vent switch typically mounted be-
side hall controller.
2
side hall controller.
1
1
C
2
C
2
Air into DM
Air into DM
fitted with
remove and
Motorised Diverting Branch
nts shown.
DM - Operating Instructions, Installation Instructions, Wiring diagrams
Dry-Matic Maintenance
to indicate it is time to clean the filters.
Air from Attic
Air from Attic
Air from Out-
Air from Out-
side
Motorised Diverting Branch
side
Can divert intake from attic to cooler
Power Supply Transfomer
Power Supply Transfomer
User Menu
"Reset the Timer -
Summer Vent Kit
outside air
User instructions continued on next pages
DMFS
Filter Bag
(air intake in attic)
DMFB
Filter Box
DMFC Carbon Filter
(inside DMFB)
Y".
Toggle Catch
Filter Sock
SOCK - filter
Tube
SE/SE
inline Filter sock
Version 3.1.765 August 2019
3