DRYDEN AQUA DA-GEN Kullanıcı Kılavuzu - Sayfa 9
İnvertör DRYDEN AQUA DA-GEN için çevrimiçi göz atın veya pdf Kullanıcı Kılavuzu indirin. DRYDEN AQUA DA-GEN 9 sayfaları.
Ayrıca DRYDEN AQUA DA-GEN için: Kullanıcı Kılavuzu (13 sayfalar)
Connection
WIFI module
8.19
Once the WIFI module is connected to the network with both lights ON, enter in www.vistapool.es.
Access the Register option and enter all the data requested. The unit ID node can be found on your device
(see section 8. System Settings - screens 8.13 & 8.14). Upon completion of the process, you will have
total control of your pool, will be able change parameters such as setpoints, filtration hours and turn ON/
OFF any auxiliary relays.
9. SALINITY*
9.1
9.4
9.2 To acknowledge this measure, press OK in Salinity in the Electrolysis/Hydrolysis
menu (the process takes between 2 and 5 minutes - display 9.4). You can adjust the
system measure using a external salt measurer (display 9.5).
9.3 If you do not have a temperature probe, enter the value manually for greater
accuracy. The lecture is influenced by many factors, like the water temperature or
the pH. Remenber to do the adjustment every 2-3 months.
* Atenttion: Option only available for some models.
3
Acid deposit
4
level
TANK
4
5
&
5
6
110-230 V
POTENTIALFREIE KONTAKTE
max. 3.15 A
1 2 3 4 5 6
7 8 9
10 11 12 13 14
N
L
FILTER PUMP
Filtration control
A1 A2
7
&
8
14
11
12
Variable Speed Pump
1
slow
2
medium
3
fast
4
common
Green LEDs
(ON)
red
yellow
1
2
green
black
3
4
8.20
9.2
9.1 Salinity: The device
9.5
shows a measurement
of salt in water in g/l,
as well as the date and
water temperature of
the last reading.
12. LEVEL SENSOR (Tank)
Connect a level sensor to your device so you can control at all times the volume available in the tanks of chemicals that your system
commonly uses. Contact your installer/provider to activate the sensor. This way you can ensure that the dosing pumps never run out of
product and doses in vacuo, avoiding possible damages.
13. VARIABLE SPEED PUMP
13.1
13.4
8.1 WIFI SETTINGS
8.15
8.16
8.21
8.22
Cover
1
&
5
9.3
1
2
3
4
5
6
7
8
10.1 Cover: Connection of automatic cover.
10.2 Reduction of chlorine production in percent, when the pool cover is closed.
With the cover closed is not necessary for the system to run at 100%. With this
parameter, regulates the optimum amount of chlorine generation.
Optional Flow switch
Mechanic security
flow switch. Stops the
hydrolysis/electrolysis and
the dosing pumps if there
is no water flow.
13.2
13.5
6
8.17
8.15 Internet: Once the WIFI module is connected, restart
your unit. In the Settings menu will appear the Internet option.
8.16 WIFI: Select WIFI to scan the available networks
accessible to the module. The search will be done
automatically.
8.17 Select the desired network accessible to the WIFI module.
8.18 Enter the password in the pop-up keyboard. Scroll up and
down with the up/down keys and left to right with the plus/
minus keys. To select a letter press the OK.
8.19 Configuration: For a more detailed configuration enter
this menu or contact your installer.
8.21 Status: Check the status of your connection.
8.22 Test connection: Check that your connection has been
successfully established.
10. COVER
10.1
11. FLOW SWITCH
It is possible to add an external
1
flow switch to the system.
2
Connect as shown in the image
3
and contact your installer for
4
activation. The titanium cell
5
6
includes a gas flow sensor, you
7
can combine both for better
8
control.
Flow switch
FL1
2
5
&
13.3
13.1 Variable Speed Pump: To install a
Variable Speed Pump contact your installer.
13.2 a 13.6 After connecting the pump, you
can individually assign each filtration period
a different speed
F: fast, M: medium and S: slow.
13.6
13.7
8.18
10.2
13.7 Filter cleaning:
To clean the filter
with a Variable
Speed Pump, you
should use the
fastest speed.