Daikin FTKS60KVM Servis Kılavuzu - Sayfa 5
Hava Kontrol Cihazları Daikin FTKS60KVM için çevrimiçi göz atın veya pdf Servis Kılavuzu indirin. Daikin FTKS60KVM 20 sayfaları. Removal procedure, 5.0/6.0/7.1 kw class, 15000/18000 btu/h class
Ayrıca Daikin FTKS60KVM için: Servis Kılavuzu (20 sayfalar)
![Daikin FTKS60KVM Servis Kılavuzu](/uploads/products/server2/1534813/1534813.jpg)
Si041254EE
2. Front Panel
Warning
Step
1
Open the front panel
over the position where
it stops.
2
Slide the front panel to
the right and release
the left shaft.
3
Release the right shaft
in the same way.
4
Remove the front panel.
Removal Procedure
Be sure to wait for 10 minutes or more after turning off all power supplies before
disassembling work.
Procedure
Front panel
Points
(R23428)
When reassembling the front
panel, fit the right and left
shafts one by one into the
grooves and fully push them
into position.
(R2754)
(R2755)
Front Panel