LRX Series Mounting
Connect conduit end with input leads to existing
18
junction box and make proper connections. Connect
the black, white and green/yellow wire of the input
leads to the black, white and green wires using twist-on
wire connectors and close junction box.
Optional dimmer: When connecting a dimming
controller, wires must be run through another separate
knockout hole. Connect the violet (dimming +) and
gray (dimming - ) wires to the violet and gray wires of
the fixture.
Note: Cap unused dimming leads with wire nuts
Adjusting Lumen Output
19
(for compatible fixtures only)
Note:
For 1000/650lm luminaires, the default lumen output is 1000lm. Push the switch up to activate the 650lm setting.
For 4000/3000lm luminaires, the default lumen output is 4000lm. Push the switch up to activate teh 3000lm setting.
For dimming device compatibility for 0-10V and phase
cut dimming, please refer to:
www.gecurrent.com/dimming