5. Installation precautions
IMPORTANT: make sure each product is at least two metres away from other devices, except other detectors.
The detector must be placed:
• at a height of 0.8 to 1.2 m,
• perpendicular to entrance points to be
protected to ensure intruders are quickly
detected,
Right
Wrong
• perpendicular to the
ground so that the
upper detection
zone is parallel to
the ground. If the
detector is at a
slope in relation to
the ground, its
H
operation may not
be as reliable.
The detector must not be placed:
• in a location where the detection beams
are likely to be directly or indirectly
impacted by the sun's rays or by a very
powerful source of light,
• facing a moving object (branches, bushes,
curtains, etc.),
• directly on a metal wall or close to sources
of interference (e.g. electricity meter) or
ventilation (air conditioning, heat pump,
etc.).
21