Insert the plug assembly into the socket (inverter end) and lock each
other by the coupling twist.
DC Wiring
Turn off the DC switch.
Choose 12 AWG wire to connect the PV module.
Trim 6mm of insulation from the wire end.
Separate the DC connector as below.
Insert striped cable into pin contact and ensure all conductor strands
are captured in the pin contact.
Plug
Pin contact Cable nut
T SERIES