Disarming the System
Disarming from an LED Keypad:
Enter the premises through a designated Exit/Entry door; entering by any other door will sound an
immediate alarm. As soon as the Exit/Entry door is opened, the keypad will beep to indicate that the
system should be disarmed. Go to the keypad and enter your access code. If an error is made
entering the code, press the [#] key and enter your code again. As soon as the correct code is
entered, the Armed light will go out and the keypad will stop beeping.
The correct access code must be entered before the entry delay period expires. If a valid access
code is not entered during this time, the system will go into alarm. The entry delay time may be
changed by your installer.
If an alarm occurred while the system was armed, the Memory light and the zone light corresponding
to the zone which caused the alarm will flash for 30 seconds. After the 30 second period, the Memory
light and zone light will stop flashing and the panel will return to the Ready state. Pressing the [#] key
during the 30 second period will cancel the alarm memory display. To view other alarms, press [ ][3].
If a trouble was detected when the panel is disarmed, the Trouble light will turn ON (See "Viewing
Trouble Conditions" on page 12 to determine the source of the trouble.) Please note that troubles will
not display while the system is in the Alarm Memory Display mode.
Disarming from an LCD Keypad:
Upon entering through a designated Exit/Entry door, the keypad will beep and the entry delay will
commence, reminding you to disarm the system. The keypad will display the following message...
Enter your access code. If an error is made in entering the code, press the [#]
Entry Active
Enter Your Code
key and enter the code again. When a valid access code is entered, the keypad
will stop beeping. If no alarms occurred while the panel was armed, and there are
no troubles, the display will read...
System Disarmed
After about five seconds, the system will return to the Ready state and the display
No Alarm Memory
will read...
Enter Code to
Arm System
If an alarm occurred while the system was armed, this message will be displayed.
View Memory
< >
Use the arrow (< >) keys to view which zones caused the alarm. If a zone is still in
"Zone of Alarm"
alarm, the display will show the following message to indicate that a zone is open...
Secure System
Before Arming < >
Upon disarming and if a trouble is present, this message will be displayed. Use the
Enter Code to
Arm System
< >
arrow (< >) keys to view which troubles are affecting the system (see "Viewing
Trouble Conditions" on page 12).
NOTE: If you return and find that an alarm has occurred while you were away, it is possible that
an intruder may still be on the premises. Go to a neighbour's house, and call the local police to
investigate.
The alarm memory is cleared each time the panel is armed so that any alarms showing are
alarms that occurred only during the last armed period.
6
Zone Bypassing
The zone bypassing function is used when access is needed to part of the protected area while the
system is armed. Zones which are temporarily out of service due to damaged wiring or contacts may
be bypassed to allow system arming until repairs can be made.
Bypassed zones will not cause an alarm. Zones cannot be bypassed once the system is armed.
Bypassed zones are automatically cancelled each time the system is disarmed and must be reapplied
before the next arming.
NOTE: For security reasons, your installer may program the system to prevent you from
bypassing certain zones.
Bypassing zones reduces your security protection. If you are bypassing a zone due to damaged
wiring or contacts, please call a service technician immediately so that the problem can be
resolved and your system returned to proper working order.
Do not unintentionally bypass zones when you arm your system.
To bypass zones from an LED keypad:
Start with the system in the Ready state. Enter [ ][1][Zone number(s) to be bypassed].
Enter the zone number(s) as a double digit from 01 to 32. As each zone is bypassed, the corresponding
zone light will turn ON. If a zone is bypassed by mistake, press that zone number again and the zone
light will turn OFF, indicating that the zone is not bypassed. Press [#] to return to the Ready state.
When the system is armed, the Bypass light will be ON if one or more zones are bypassed.
To bypass zones from an LCD keypad:
To bypass a zone, the system must be in the Ready state. The display will read...
Press the [ ] key to enter the functions menu. The display will read...
Enter Code to
Arm System
Press the [ ] key to enter the zone bypassing mode. The display will read...
Press (*) for
< >
Zone Bypass
Use the arrow (< >) keys to find the zone to be bypassed and press the [ ] key to
Zone Search
< >
select it. The display will read...
"Zone Name"
"B" will appear on the display to show that the zone is bypassed. To unbypass a
Zone Search
< >
"Zone Name"
B
zone, enter the zone number; the "B" will disappear from the display to show that
the zone is no longer bypassed.
This display will be shown if a zone was open when you entered the bypassing
Zone Search
< >
command. The open zone will be represented by "O". If you bypass the open zone,
"Zone Name"
O
the "O" will be replaced by a "B".
To exit the bypassing mode and return to the Ready state, press the [#] key.
11