Testing and Troubleshooting

S
5.1 Camera Testing
Cameras connected to the PC5108L can be tested on a regular basis.
The DLM-4L must be connected in order to use the testing feature.
Each camera must be enabled for testing. There is one Camera X
Test Enable/Disable option for each camera. Not all cameras must
be selected for testing. By default, the test feature is enabled for each
camera.
If Periodic Camera Test Enable/Disable
Periodic Camera Test Enable/Disable
Periodic Camera Test Enable/Disable is ON, a camera test will
Periodic Camera Test Enable/Disable
Periodic Camera Test Enable/Disable
occur every 30 minutes. When OFF, there are camera tests:
1. Upon a system test: This test is user-initiated. See the PC5015
Instruction Manual for testing instructions.
2. Upon exiting Installer's Programming.
The test will take up to five seconds to perform. If the camera test
result is successful, normal system operation will continue. If the
camera test produces bad results from any of the cameras, a system
trouble will be initiated. The message "Camera X Trouble" will be
logged to the event buffer. When the trouble condition has cleared,
the message "Camera X Trouble Restore" will be logged.
A bad camera test result could be due to a number of factors, includ-
ing bad camera wiring, loss of power to the camera or a faulty unit.
To test the Downlook Remote Trigger feature, perform the following:
1. Enter [*][8][Installer's Code][906].
2. Press number keys [1]-[4] to transmit remote trigger script via
the appropriate path:
[1] telephone number 1 via landline
[2] telephone number 2 via landline
[3] telephone number 1 via LINKS
[4] telephone number 2 via LINKS
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
Camera X Test Enable/Disable ................................... Subsection [60]
Periodic Camera Test Enable/Disable ........... Section [017] Option [7]
Local Test of Downlook Remote Trigger ......................... Section [906]
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
5.3 Software Default
To restore the PC5108L programming to the factory default settings,
perform the following:
1. Enter PC5108L module programming by pressing
[*][8][Installer's Code][806].
2. Enter programming subsection [99].
3. Enter [55]. Once [55] is entered, the module's default
programming will be restored.
For instructions on restoring the default programming of the main
panel or any other connected module, see the PC5015 Installation
Manual.
E
C
T
I
O
10
N
5