DSC Power 832 Kurulum Kılavuzu - Sayfa 8

Kontrol Ünitesi DSC Power 832 için çevrimiçi göz atın veya pdf Kurulum Kılavuzu indirin. DSC Power 832 17 sayfaları. Central station talk / listen module
Ayrıca DSC Power 832 için: Kullanım Kılavuzu (11 sayfalar), Kullanım Kılavuzu (18 sayfalar), Kullanıcı Talimatları (2 sayfalar), Kurulum Talimatları Kılavuzu (12 sayfalar), Kullanıcı Kılavuzu (20 sayfalar), Kurulum Talimatları (2 sayfalar), Kurulum Talimatları (2 sayfalar)

DSC Power 832 Kurulum Kılavuzu
M O D U L E
Since four images can be stored by the DLM-4L for each event, four
timing and camera entries are required. Entering 00 for the timing
means that the picture will be taken without delay. Entering 00 for the
camera means that no picture will be taken.
The programming sections resembles the following example (all
entries by default are [00]):
[01] Zone 1
During the delay (dwell time) the PC5108L remains (dwells) on that
camera until the time expires, after which the next camera in the
script is selected. In the above example, when Zone 1 goes into
alarm, tamper or fault, the DLM-4L will:
• immediately select Camera 3 and take a picture;
• at100 ms, switch to Camera 5 to take a 2nd picture;
• at 300 ms after this, switch to Camera 2 to take a 3rd picture;
• wait a further 400ms before resuming in either Pre-Trigger
monitoring or Camera select monitoring.
The DLM-4L will follow the programmed Timing and Camera settings
for all events. By default, if another Downlook-initiating event occurs
while there are pictures in memory (not yet transmitted), the DLM-4L
will not overwrite the existing pictures.
If the Pictures Can Be Overwritten option is enabled, the DLM-4L
will overwrite the pictures in memory when a new Downlook-initiating
event occurs.
For Delay type zones, timing and camera settings will be followed when
the zone is violated. If the user disarms the system before the entry delay
expires, the pictures will be erased. If the system is not disarmed, an
alarm will occur and the stored pictures will be transmitted.
The various Downlook-initiating events/triggers are described below:
Event-initiated Downlook
The indicated events will initiate Downlook if the corresponding
Timing and Camera entries are programmed. Some events are
grouped under one heading. These events are the following:
• Zone X Alarm/Tamper/Fault: Downlook will be initiated when the
corresponding zone exhibits an alarm, tamper or faulted
condition.
• Keypad Events: these events include Duress alarm, FAP alarms,
Keypad Lockout and Auto-Arm Cancel/Postpone.
• Closings: these events include arming by user code and all
special closings (DLS, auto-arm, keyswitch, quick arm or
maintenance code). A Late To Close will cause the closing script
to be run even if Auto-Arming is not enabled.
• Openings: these events include disarming by user code and all
special openings (DLS, keyswitch, or maintenance code).
Unidentified Wireless Keys should not be used to initiate Downlook.
O P E R A T I O N
T
C
0 1 0 3
l _ ____ l _ ____ l _ ____ l _ ____ l
A N D
P R O G R A M M I N G
T
C
0 3 0 5
0 4 0 2
l _ ____ l _ ____ l _ ____ l _ ____ l
l _ ____ l _ ____ l _ ____ l _ ____ l
6
T
C
T
0 0 0 0
l _ ____ l _ ____ l _ ____ l _ ____ l
C