Atsumi Electric IR36EXA Kurulum Kılavuzu - Sayfa 3

Güvenlik Sensörleri Atsumi Electric IR36EXA için çevrimiçi göz atın veya pdf Kurulum Kılavuzu indirin. Atsumi Electric IR36EXA 8 sayfaları. Passive infrared detector

2. Two (2) detectors on a loop
E+
E-
1
C
Power
Alarm
Controller
I
Power input shall be parallel, and alarm and tamper outputs shall be series connection.
I
Tamper output shall be connected to the input terminals of a security controller.
5

Installation

1 Unscrew the lock screw and turn the body unit
counterclockwise to detach from the base unit.
3 Determine initial setup. Please refer to "6. Initial Setup" for details.
4 Determine coverage. Please refer to "8. Coverage Setup" for details.
5 Align direction of both arrows then match Mark A (or V-shaped protrusion A) of the body unit with Mark B of the base unit.
Then turn the body unit clockwise to fix it in a Lock Position (Mark C).
6 Screw the lock screw to fix the body unit on the base unit.
Refer to "11. Coverage" on page 6 to install the unit so that the expected movement of an intruder will be across
the field of view.
T
T
1
2
Tamper
Power Alarm
Arrows
1
2
3
4
5
Tamper
Detector
2 Firmly mount the base unit on ceiling with the mounting
screws provided, and route wiring as necessary to the
rear of the base and through the wiring hole.
3
6
1
2
3
4
Power Alarm
Detector
Wiring hole
Knockout
Mark B
Mark A
V-shaped protrusion A
5
6
Tamper
Mark C
(Lock position)