Attero Tech AXON D2FLEXio Kullanıcı Kılavuzu - Sayfa 9

Kayıt Ekipmanları Attero Tech AXON D2FLEXio için çevrimiçi göz atın veya pdf Kullanıcı Kılavuzu indirin. Attero Tech AXON D2FLEXio 11 sayfaları. Dual analog flex i/o networked audio interface

3.3– Factory Reset
*************************** IMPORTANT ************************
The factory reset returns the entire device to its factory defaults.
Using this feature will mean all custom Dante™ settings and all
audio power-on default settings will be cleared.
*******************************************************************
*NOTE: The factory reset is a useful way of quickly restoring
communications with a device which has an unknown static IP
address as a factory reset returns the device's network settings
to getting a dynamic IP. Having successfully completed a factory
reset of the device, setting the PC's IP address to also obtain a
dynamic IP address should then allow the PC to communicate fully
with that device.
Figure 10 - Reset button access
The factory reset button is accessed through a small hole on the
back of the unit using a small screwdriver or a paperclip. A factory
reset is initiated by pressing and holding this button for 5
seconds or more while the device is powered on.
correctly, the status LED will change to white. This indicates the
D2FLEXio has entered factory mode.
If Dante Controller or other Dante device discovery software is in
use, the device may show up as "Ultimo-xxxxxx". This simply
indicated the device is in factory mode.
To complete the factory reset and revert back to normal
operation. Simple toggle the factory reset button again with a
short press and release or power cycle the device.
Having applied a successful factory reset, on the Dante™/AES67
side, customized device name and channel names will be cleared
and any receive flow subscriptions will be removed. The network
settings will also be reset so the device will return to retrieving
an IP address dynamically.
3.4 – Firmware Updates
The D2FLEXio has the ability to be updated in the field should it
be required. Updates are applied via the network using Attero
Tech unIFY Control Panel's smart firmware update facility. The
latest D2FLEXio SFU file is available from the
customer
portal.
If done
Attero Tech
1315 Directors Row Suite 107 Fort Wayne, IN 46808 ⁞ (260)496-9668 ⁞ www.atterotech.com
Page 6