2.1 – Mounting
It is recommended that the unit be secured to a flat surface with a screw through each mounting flange. Dimensions for
mounting are show in the Figure 2 below. Use a No. 6 screw of a type and size that is applicable to the surface to which
the unDIO2X2+ will be attached.
Notes for mounting: All connections to the unDIO2X2+ should be made before the power is applied.
Attach any audio sources that will be used to the inputs. The inputs are balanced so be sure to check what
o
output type the source to be connected uses in order to find how to connect it correctly (see Hardware
Connections section).
Attach the outputs to the required audio devices. The outputs are balanced so be sure to check what input type
o
the device to be connected requires in order to find how to connect it correctly (see Hardware Connections
section 2.3 for further details).
*Note: All Attero Tech products are tested using UTP cabling and it is recommended that UTP cabling be used when
installing them. STP cabling can be used for installation though care must be taken not introduce grounding issues into
the system by doing so.
When powering using PoE:
Attach the Dante port to a spare PoE-enabled port on a PoE switch using a CAT-5 cable. If a mid-span injector is
o
being used, connect a spare input port to the Dante network switch using a CAT-5 cable, and then connect the
corresponding output port to the Dante port of the unDIO2X2+.
When powering using an optional external supply:
Attach the Dante port to a spare port on the Dante network switch using a CAT-5 cable.
o
Attach the power supply to the power input jack and then power up the external supply.
o
If all steps are performed correctly, the power light on the front should be lit. Some of the Dante Status LED's may also
be lit or flashing.
There may also be some activity on the unDIO2X2+ Dante Ethernet connector LED indicators. With no Dante network,
both LEDs will remain off. If an active connection is made both LEDs will come on and if there is network activity, the
yellow LED will then flash.
Attero Tech LLC 2018
Figure 2 - Mounting Information
Page 6
614-00037 Rev 01_b