Absolute Process Instruments Cecomp F16DRNBL Series Talimatlar

Verici Absolute Process Instruments Cecomp F16DRNBL Series için çevrimiçi göz atın veya pdf Talimatlar indirin. Absolute Process Instruments Cecomp F16DRNBL Series 4 sayfaları. Programmable 4-wire digital pressure transmitters

Cecomp
Programmable 4-Wire Digital Pressure Transmitters
®
Ranges and Resolution
See table below. Consult factory for special engineering units.
Resolution is fixed as indicated in table.
‡ -HA option not available
PSI
inHg/PSI
Res
Res
3PSIG
.001 –30V15PSIG
.1
5PSIG
.001 –30V100PSIG
.1
15PSIA
.01 –30V200PSIG
.1
15PSIVAC
.01
inH
O
Res
2
±15PSIG
.01
85INH2OG
.01
15PSIG
.01 140INH2OG
.1
30PSIA
.01 400INH2OA
.1
30PSIG
.01 400INH2OVAC
.1 ±1000CMH2OG
60PSIG
.01 ±400INH2OG
1
100PSIA
.1
400INH2OG
.1
–15V100PSIG
.1
850INH2OA
1
100PSIG
.1
850INH2OG
1
ftH
O
–15V200PSIG
.1
Res
2
200PSIG
7FTH2O
.1
.001
300PSIG
12FTH2O
.1
.01
500PSIG
.1
35FTH2O
.1
1000PSIG
1
70FTH2O
.1
2000PSIG
1
140FTH2O
.1
3000PSIG
1
230FTH2O
.1
5000PSIG
480FTH2O
1
.1
oz/in
700FTH2O
2
Res
.1
50ZING
1150FTH2O
.01
1
80ZING
.1
2300FTH2O
1
240ZINA
.1
4600FTH2O
1 –100V700KPAG
240ZINVAC
.1
6900FTH2O
1
mmHg
±240ZING
.1
Res
240ZING
150MMHGG
.1
.1
480ZINA
260MMHGG
.1
.1
480ZING
.1
760MMHGA
.1
inHg
Res
760MMHGVAC
.1
6INHGG
.001 ±760MMHGG
1
10INHGG
.01 760MMHGG
.1 –0.1V1.4MPAG
30INHGA
.01 1600MMHGA
1
30INHGVAC
.01 1600MMHGG
1
±30INHGG
Torr
.01
Res
30INHGG
.01
760TORRA
.1
60INHGA
.01
760TORRVAC
.1
60INHGG
.01 1600TORRA
1
mbar
120INHGG
.1
Res
200INHGA
200MBARG
.1
.1
–30V200INHGG
350MBARG
.1
.1
200INHGG
.1
1000MBARA
1
–30V400INHGG
.1
1000MBARVAC
1
400INHGG
.1 ±1000MBARG
1 ±1000GCMG
600INHGG
.1
1000MBARG
1
1000INHGG
2000MBARA
1
1
2000INHGG
2000MBARG
1
1
4000INHGG
bar
1
Res
atm
Res
1BARA
.001
1ATMA
.001
1BARVAC
.001
1ATMVAC
.001
±1BARG
.001
±1ATMG
.001
1BARG
.001
1ATMG
2BARA
.001
.001
2ATMA
2BARG
.001
.001
2ATMG
.001
4BARG
.001
4ATMG
.001
7BARA
.001
7ATMA
.001
7BARG
.001
7ATMG
.001 –1V7BARG
.01
–1V7ATMG
14BARG
.01
.01
14ATMG
.01 –1V14BARG
.01 –1V14KGCMG
–1V14ATMG
20BARG
.01
.01
20ATMG
.01
35BARG
.01
34ATMG
.01
70BARG
.01
70ATMG
.01
140BARG
.1
140ATMG
.1
200BARG
.1
200ATMG
350BARG
.1
.1
340ATMG
.1
C E CO MP
Div. of
Accuracy
Accuracy includes linearity, hysteresis, repeatability
Standard accuracy: ±0.25% of full scale ±1 least significant digit
HA accuracy option: ±0.1% FS ±1 LSD, see ranges for availability
Sensor hysteresis: ±0.015% FS, included in accuracy
mmH
O
Res
Sensor repeatability: ±0.01% FS, included in accuracy
2
2100MMH2OG
1
Display
4 readings per second nominal display update rate
3500MMH2OG
1
4 digit LCD, 0.5" H and 5 character 0.25" H alphanumeric
cmH
O
Res
2
DRBL: Red LED backlight on when gauge is on
210CMH2OG
.1
Controls
350CMH2OG
.1
SEL
1000CMH2OA
1
TEST
1000CMH2OVAC
1
s Up:
t Down:
1
Zero/tare function can be enabled or disabled
1000CMH2OG
1
Calibration
2100CMH2OA
1
User settable pass code required to enter calibration mode
2100CMH2OG
1
All pressure and absolute models: zero, midpoint, span
kPa
Res
All vacuum models: –span, –midpoint, zero
Vacuum/pressure models: –span, zero, +midpoint, +span
20KPAG
.01
±15 psi models: –span, –midpoint, zero, +midpoint, +span
35KPAG
.1
Output Characteristics
100KPAA
.1
Updated approximately 16 times per second
100KPAVAC
.1
User scalable pressure range to correspond to output
±100KPAG
.1
-I: Current output, 4-20 mA DC
100KPAG
.1
Output drive (compliance) determined by power source
6,553 counts over sensor range
200KPAA
.1
-V: Voltage output, 0-2 VDC into 5k ohm or greater
200KPAG
.1
6,553 counts over sensor range
400KPAG
.1
-BV: Bipolar voltage output (–2 - 0 - 2 V) for ±15 psig sensor only
700KPAA
.1
±2 VDC into 5k ohm or greater
13,107 counts over sensor range
700KPAG
.1
Power
1
8-24 VAC 50/60 Hz or 9-32 VDC
1400KPAG
1
Gauge is on when power is on. Designed for continuous operation.
–100V1400KPAG
1
DR:
30 mA maximum
2000KPAG
1
DRBL:
Approximately 40 mA maximum
3500KPAG
1
Weight
7000KPAG
1
9.5 ounces (approx.), shipping wt. 1 pound (approx.)
MPa
Res
Housing
F16DR: Extruded aluminum case, epoxy powder coated, ABS/
1.4MPAG
.001
polycarbonate bezel (aluminum bezel optional), front and rear
.001
gaskets, polycarbonate label
2MPAG
.001
F16DRN: ABS/polycarb. NEMA 4X case, rear gasket, polycarb. label
3.5MPAG
.001
Connection, Material, Media Compatibility
7MPAG
.001
1/4" NPT male fitting. All wetted parts are 316L stainless steel.
14MPAG
.01
Overpressure, Burst, Vacuum
20MPAG
.01
Ranges using 3000 psig sensor: 5000 psig
35MPAG
.01
Ranges using 5000 psig sensor: 7500 psig
All others:
g/cm
2
Res
3000 psi, 5000 psi, and 4 digit ranges 112.5% full scale out-of-
200GCMG
.1
range display: 1– – – or I –.–.–.–
350GCMG
.1
4 X sensor burst pressure rating, or 10,000 psi, whichever is less
1000GCMA
1
Vacuum service: 15 psia, ±15 psig, 15 psig, 30 psia,
1000GCMVAC
1
Under-range display (non-vacuum sensors): –Err
1
Environmental
1000GCMG
1
Storage temperature:
2100GCMA
1
Operating temperature:
2100GCMG
1
Compensated temperature:
kg/cm
2
Res
1KGCMA
.001
1KGCMVAC
.001
±1KGCMG
.001
1KGCMG
.001
2KGCMA
.001
2KGCMG
.001
4KGCMG
.001
7KGCMA
.001
7KGCMG
.001
–1V7KGCMG
.01
14KGCMG
.01
2.88"
.01
20KGCMG
.01
35KGCMG
.01
70KGCMG
.01
140KGCMG
.1
200KGCMG
.1
350KGCMG
.1
1.65"
A
P
BSOLUTE
ROCESS
Select display for setup
Set output to test level when in test mode
Increase when in test or calibration mode
Decrease when in test or calibration mode
2 X pressure range
100 psig, 100 psia, 200 psig sensors
–40 to 203°F (–40 to 95°C)
–4 to 185°F (–20 to 85°C)
32 to 158°F (0 to 70°C)
88888
X X X X X
2
SEL
TEST
s
t
Cecomp Electronics / Made in USA
0.75"
¼" NPT
3.38" Standard
3.5" NEMA 4X
3 ft long,
3 ft long,
4-conductor
4-conductor
3.0"
22 AWG
22 AWG
shielded
shielded
NEMA 4X
cable
cable
Allow 1"
Allow 1"
clearance
clearance
Turn at hex
Turn at hex
fitting
fitting
only!
only!
2.0"
1220 American Way Libertyville, IL 60048
I
NSTRUMENTS
F16DR, F16DRN
O ±0.25% Test Gauge Accuracy
O 316L Stainless Steel Wetted Parts
O Low Voltage Powered
O 4-20 mA or 0-2 V Analog Output
O Output Test Function
F16DR
F16DRN
Quick Link:
cecomp.com/xmtr
How to Specify
F16DR range - output - options
F16DRBL range - output - options
F16DRN range - output - options
F16DRNBL range - output - options
Range—see table at left
psi = PSI
torr = TORR
inHg = INHG
mmH
O = MMH2O
2
oz/in
2
= ZIN
kg/cm
2
= KGCM
inH
O = INH2O
g/cm
2
= GCM
2
ftH
O = FTH2O
kPa = KPA
2
mmHg = MMHG
MPa = MPA
G = gauge reference pressure
VAC = gauge reference vacuum
A = absolute reference
Output
I
Specify:
4-20 mA
V
0-2 V
BV
±2 V for ranges using ±15 psig sensor only
Options—add to end of model number
High accuracy, ±0.1% FS ±1 LSD. See table at left for
HA
availability.
PM
Panel mount, 4.1" x 4.1", n/a NEMA 4X
CC
Moisture resistant circuit board conformal coating
CD
Calibration data; 5 test points and date
NC
NIST traceability documentation, 5 points and date
Accessories—order separately
WMPSK Wall mount power supply kit, 115 VAC/12 VDC
SCR14SS
Filter screen fitting keeps debris out of gauge
sensor. Use for food vacuum packaging applica-
tions. 303 SS body, 100 micron 304 SS screen.
cecomp.com
800-942-0315
H H H H H H
H H H H H
H H H H H H
H H H H H
H H H H H H
H H H H H
H H H H H H
H H H H H
H H H H H H
Made in USA
NEMA 4X
Housing
Type
Standard housing
Standard housing,
backlit display
NEMA 4X housing
NEMA 4X housing,
backlit display
mbar = MBAR
bar = BAR
cmH
O = CMH2O
2
atm = ATM
© 08-18