Aube Technologies TH132 F Kullanıcı El Kitabı - Sayfa 3

Kontrol Ünitesi Aube Technologies TH132 F için çevrimiçi göz atın veya pdf Kullanıcı El Kitabı indirin. Aube Technologies TH132 F 3 sayfaları. Programmable control module
Ayrıca Aube Technologies TH132 F için: Kullanıcı El Kitabı (2 sayfalar), Kullanıcı El Kitabı (3 sayfalar), Kullanıcı El Kitabı (2 sayfalar)

Aube Technologies TH132 F Kullanıcı El Kitabı
The PB130-230 power base is designed to power a TH13x
Series control module. The resistive load must not exceed
3680 watts (NI) @ 230 VAC (16 A).
Turn off power to the heating system at the main power panel
to avoid electrical shock. Installation should be carried out by
an electrician.
All work must conform to the applicable country standards for
electrical installations and wiring.
This thermostat should be connected on a circuit equipped
with a fuse or a circuit breaker. It must be installed on a certi-
fied electrical box.
For a new installation, choose a location about 1.5 m above
the floor.
For electric baseboards, convectors and fan-forced heaters,
the thermostat must be installed facing the heating system.
The thermostat must be installed on an inside wall.
Avoid locations where there are air drafts (top of staircase, air
outlet), dead air spots (behind a door), direct sunlight or con-
cealed chimneys or stove pipes.
!
One (1) PB130-230 power base
"
One (1) floor sensor (for AF and F control modules only)
#
One (1) wall plate (optional, in certain countries)
Model: PB130-230
Supply: 230 VAC, 50 Hz
Load: 16 A maximum (resistive only)
Power: 3680 Watts (NI) @ 230 VAC
Approval: EN60730-2-9 / EN50081-1 / EN50082-2
Storage: -20°C to 50°C
Protection: Class 2
Protection
degree: IP20
Automatic
action: Type 1.B
Environment: Normally polluted
Size (H • W • D)
: 2.95 x 2.95 x 0.55 in. (75 x 75 x 14 mm)
NOTE:
The terminals are designed to handle a cross-section of
wire measuring 0.33 to 3.1 mm
If you have any questions concerning the installation of the
PB130-230 power base, contact our technical support team at:
705 Montrichard
Saint-Jean-sur-Richelieu
Quebec, Canada J2X 5K8
Tel.: (450) 358-4600
Toll Free: 1-800-831-AUBE
Fax: (450) 358-4650
For more information on our products, visit us at
www.aubetech.com
2
.
10 rue Ampère
95500 Gonesse
France
33 (0) 1 34 07 99 00
33 (0) 1 34 07 99 19
!
Remove the screw holding the
control module to the power base
and lift the lower part upwards.
The screw cannot be completely
removed.
"
If you have a wall
plate: Before making
the connections, make sure that the base
covers the electrical box entirely. If not,
insert the wall plate on rear of the base.
NOTE:
The wall plate can be used for aesthetic
purposes only.
#
Connect the wires:
Power (L,
N):
Terminals 1 and 5
Load (L,
N):
Terminals 2 and
4
see notes 1 & 2
Pilot Wire
(F.P.):
Terminal 3
see note 3
Floor
sensor:
Terminals 6 and 7
(no polarity needs
to be respected)
Note 1
If the load is driven through a contactor, it is recommended
to install a snubber at the contactor's coil terminal to
extend the contactor's life expectancy and ensure a good
operation of the thermostat.
Note 2
Compatible with TH131 control module only.
Note 3
The floor sensor wire cannot lay across or next to any
heater wires. For maximum performance, the sensor must
be centered between the wires at a maxi-
mum temperature of 80°C.
$
Push wires into the electrical box and
secure the base to the electrical box
anchorage. The head of the screw
must be less than 2 mm thick.
%
BEFORE mounting the control
module onto the base, configure the
switches (if any) and install the con-
trol module onto the base
user
guide).
&
Return power to the heating system.
WARNING: this power base must be used
heating cycles (temperature control). Depending on the selected
control module, make sure that the switch is set at
AUBE TECHNOLOGIES INC. TWO (2) YEAR LIMITED WARRANTY
This product is guaranteed against workmanship defects for a two-year period following
the initial date of purchase. During this period, AUBE Technologies Inc. will repair or
replace, at our option and without charge, any defective product which has been used
under normal conditions.
The warranty does not cover delivery costs and does not apply to products poorly
installed or randomly damaged following installation. This warranty cancels and
replaces any other manufacturer's express or implied warranty as well as any other
company commitment.
AUBE Technologies Inc. cannot be held liable for related or random damages following
the installation of this product. The defective product as well as the purchase invoice
must be returned to the place of purchase or mailed, prepaid and insured, to the
nearest location.
(refer to the
only
with
15-minute
15
minutes.
19/01/2004
400-130-001-B