1.
Overview
This is a dual-output temperature controller with 8 programmable steps. It
contains one temperature probe and two independent outputs. One output is
for cooling device such as refrigerator and the other one is for heating device.
The temperature control can be programmed to vary with different time step
setting. Up to 8 temperature-time steps covering 33 days can be programmed.
It can be used for applications such as beer fermentation or convert a
refrigerator to kegerator. By using both cooling and heating devices, the
refrigerator can be controlled at specific temperature regardless in hot summer
or cold winter.
This controller is a plug and play controller. No wiring is needed for the heater
or cooler. Both the heating and cooling control modes are simple on/off control,
similar to a mechanical thermostat but with much higher precision due to
adjustable hysteresis band, precise sensor and digital read out. Anti-short
function is provided for cooling to protect the compressor from being turned on
with high pressure Freon.
Different operation temperature ranges of the two outputs can be set
separately. Once the cooling range is set, the controller program will
automatically limit the heating range to prevent both heating and cooling from
being turned on at the same time.
A digital silicon band gap sensor is used. The advantage is being much more
reliable in moisture environment than thermistor sensor. It can be immersed
over extended period of time. It also has a more uniform accuracy over an
entire specified temperature range.
2.
Specifications
Table 1. Specifications
Temperature Control Range
Temperature Resolution
Temperature Accuracy
Temperature Control Mode
Temperature Control Output
Timer Range
Timer Resolution
Max Programmable Time
Audio Alarm
Sensor Type
Sensor Size
Ambient Temperature
Dimension
Input Power
Sensor Cable Length
Power Cable Length
Warranty: One (1) year.
2015.06
TD400P Programmable Temperature Controller
-50 ~ 105° C, -58 ~ 221° F
0.1° C (between -9.9 ~ 99° C)
1° C (between -50 ~ 10° C, 100 ~ 120° C)
0.1° F (between -9.9 ~ 99.9° F)
1° F (between -58 ~ 10° F, 100 ~ 248° F)
0.5 ° C or 0.9 ° F
On/Off Control. Heating and Cooling
10A, 120 V or 240 VAC *
Each step: 0.1 to 99.9 Hours or 1 to 999
Minutes
0.1 Hours or 1 Minute
799.2 hours or 33.3 days (for total 8 steps)
High and low limit
Silicon Band Gap Sensor
0.25" OD (6.35 mm) x 1" (25mm) long
-20 ~ 50° C (0 ~ 120° F)
91 x 140 x 46mm
85 ~ 242 VAC, 50 Hz / 60 Hz
6 ft (2 m)
3 ft (1 m)
Version 1.1 (Oct, 2017)
*: Either heating or cooling device is limited to 10 Amps. The output voltage is
same as input voltage. When the controller is plugged into 120V AC, the
output will be 120VAC. If the controller is connected to 240 VAC, the output will
be 240VAC also.
3.
Front Panel
Display window: display temperature reading and parameters.
RUN indicator: the green LED indicator is on when the program is running.
START key: start executing the program.
PAUSE/STOP key: short press it to pause the program; long press it for 4
seconds to stop the program (only when the program is already been paused).
MUTE key: silent the alarm buzzer.
STEP key: jump to different step; check the running step.
SET key: access the program settings and parameter settings.
UP key: increase the value.
DOWN key: decrease the value.
Cooling device socket: supply power to cooling device.
Cooling device indicator: green LED indicator; it is on when the cooling
device socket is energized.
Heating device socket: supply power to the heating device.
Heating device indicator: red LED indicator lit; it is on when the heating
device socket is energized.
4.
Basic Operation
Here are the basic operating procedures to use this controller. To fully
understand the functions on this controller, please read the entire manual.
1) Connect the temperature sensor to the sensor socket that is located on the
top of the controller. Please check the alignment of the slot on the plug with the
key on the socket. (See section 12 for details.)
2) Plug the controller's power cord to a wall outlet.
3) Set up the program and system parameters. Please read the rest of this
manual for details.
4) Connect the cooling device and/or heating devices to the output sockets on
this controller.
5) Press START key to start running the program.