Auber Instruments ECT-100 Kullanım Kılavuzu - Sayfa 3
Sıcaklık Kontrolörü Auber Instruments ECT-100 için çevrimiçi göz atın veya pdf Kullanım Kılavuzu indirin. Auber Instruments ECT-100 3 sayfaları.
AUBER INSTRUMENTS
AT. Auto-tune function. Set AT to 1 then exit the menu. The display will
•
start to flash alternately between AT and the current temperature, which
indicates auto-tuning is in progress. When the display stops flashing, the
auto-tuning is finished. Now, the newly calculated PID parameters are set
and are used for the system. The new parameters will store in the
memory even the power is off
C-F. Temperature display unit. You can set the unit either to Celsius or
•
Fahrenheit.
oFS. Input Offset. oFS is used to compensate the error produced by the
•
sensor or input signal itself. For example, if the unit displays 37 degree
when the actual temperature is 32, set parameter oFS = - 5 will make the
controller display 32 degree. The displayed process temperature = actual
measured temperature + oFS.
6. Recommended Parameter for Sous Vide Cooking
The default setting: P=18, I=650, d=40, and t=20 is optimized for Sous Vide
cooking with rice cooker or steam table.
7. Connecting the Sensor to the Controller
The connector of sensor contains a slot for fitting pin connection. It also has a
spring lock to prevent disconnections from accidental pulling on the cable. To
install the to the unit, please align the slot of the female connector on the
sensor to the red mark of the male connector on the unit, then hold the tail and
push the female connector forward. To remove the connector, please pull the
spring-loaded collar of the female connector. Please see the Figure 3 and
Figure 4 below for details.
Figure 3. Install the Sensor.
Figure 4. Remove the Sensor.
2017.10
Auber Instruments Inc.
5755 North Point Parkway, Suite 99,
Alpharetta, GA 30022
www.auberins.com
E-mail: [email protected] Tel: 770-569-8420
Copyright 2007-2017, Auber Instruments All Rights Reserved.
No part of this manual shall be copied, reproduced, or transmitted in any way without the
prior, written consent of Auber Instruments. Auber Instruments retains the exclusive
rights to all information included in this document.
WWW.AUBERINS.COM
P3/3