Auber Instruments WS Series Hızlı Kılavuz - Sayfa 13
Sıcaklık Kontrolörü Auber Instruments WS Series için çevrimiçi göz atın veya pdf Hızlı Kılavuz indirin. Auber Instruments WS Series 14 sayfaları. Programmable pid temperature controller with dual probe
Ayrıca Auber Instruments WS Series için: Hızlı Kılavuz (15 sayfalar), Hızlı Kılavuz (14 sayfalar), Kullanım ve Talimat Kılavuzu (18 sayfalar), Kullanım ve Talimat Kılavuzu (18 sayfalar)
again, it will resume working in this mode. You do not need to enter any other program
steps in this mode.
To enter the single-step mode, the user need to set the parameter "PrG" to "off". Under
the normal operating mode, press and hold SET key for 2 seconds until LED display
"LCK" on the left window, and then release the SET key. The display on the right window
will show "0". Use "+" key to adjust the number to 3 and press SET key again to confirm.
Then "PrG" will be shown on the left window, and "on" or "off" in the right window. Use "+"
or "-" key to toggle between "on" to "off". Select "off" and press SET key if you want to
enter the single-step mode. Otherwise, select "on" and press SET key to enter the
program mode. The controller will go back to the normal operating mode. To set the
temperature, press SET key once, and the left window will show "C-1". Use "+" or "-" key
to adjust the temperature in the right window, then press SET to save and exit.
In single-step mode, the save and recall function (Section 9) can still work. But the
change can only be applied to C-1, i.e., you can only store your current set temperature
to the C-1 in a selected recipe, or recall the C-1 temperature from a selected recipe to
the current set temperature. Other data will remain in the memory of controller but is not
accessible under the single-step mode. To exit the single-step mode, you only need to
change the "PrG" value to "on".
Please note: In older versions, it may show PrG options as "y" or "n", instead of
"on", "off". To enter single-step mode, please select "n".
12. Examples
a.
Store your program as a recipe (Program Mode)
Before you input your program, check the PrG = on (accessed by LCK code "3"). Press
SET briefly, and enter the program below:
C-1=120, E-1=t, t-1=2.0;
C-2= 290, E-2= F, F-2=160;
C-3=130, E-3=t, F-3=30.0.
You can leave the rest of steps as their default values.
To store in program to recipe b1, long press SET key, set LCK=2, choose b1, and press
SET again to confirm and exit. Now the controller is back to the normal operating mode.
It will run on this current program, which has just been saved as recipe b1.
b.
Recall a recipe to the current program (Program Mode)
Before you input your program, check the PrG = on (accessed by LCK code "3"). Long
press SET, set LCK=2, choose b1, press set to exit.
Then recipe b1 is recalled back as the current program. The controller is back to the
13