AUBER INSTRUMENTS
Note 3. Digital sensor filter
If measurement input fluctuates due to noise, then a digital filter can be used to
smooth the input. "FILt" may be configured in the range of 1 to 6. Stronger
filtering increases the stability of the readout display, but causes more delay in
the response to change in temperature. By default, FILt is set to 1 (weakest
filtering).
Note 4. Temperature unit setting: C-F
C-F determines the temperature unit. It can be set to C (Celsius, ˚C) or F
(Fahrenheit, ˚F).
Note 5. High temperature turn off function: FF
This regulator has an automatic shut off feature, when the actual temperature is
over the limit temperature you set. The automatic output power shut off
mechanism is latched just like a limit controller. Once it is shut off, the heater will
not turn on unless the system is reset. Please check section 6.3 for details.
goto
syst
Knob
tf
Timer function
on
Knob
High temp.
ff
finishing
on
function
Knob
Timer counting
tdir
direction
dn
Knob
Temp. reading
pb
0
offset
Knob
filt
Digital filter
1
Knob
C-f
Temp. display
unit
f
Knob
rl1
off
Relay 1
mode
Figure 6. Flow chart of setting system parameters
2021.09
80
End
100
Press
Knob
Multi-function
key
key assignment
off
Press
Knob
Press
Alarm
sil2
suppression
n
for relay 2
Press
Knob
Press
Latching or pulse
lat2
action selection for
n
relay 2
Press
Knob
Press
Logic mode
lgc2
Rl-c
for relay 2
Knob
Press
Press
Relay 2
rl2
mode
off
Press
Knob
Press
Alarm
sil1
suppression
n
for relay 1
Press
Knob
Press
Latching or
lat1
pulse action
selection for
n
relay 1
Press
Knob
Press
lgc1
Knob Press
Rl-c
Logic mode
for relay 1
6.2 Mashing Parameters
Table 2. Mashing parameters
Mashing Mode Parameters
Display
Code
Description
Mashing time set
t
t
value
Mashing timer start
tSP
tSP
temp.
Mashing alarm set
ALH
ALH
temp.
Mashing ending
EO
EO
options
oScr
oScr
Overshoot correction
AttE
AttE
Attenuation constant
Note 7. Timer Function: t, tSP, EO
This timer function allows the controller to show the mashing time. It makes a
beeping sound when timed out and will display the process is ended. It can also
automatically shut off the controller's power output after time out. The time
duration is set by the t parameter for mashing mode. The unit is hour: minutes.
When timer function is enabled, the timer counting will be started by timer start
temperature, tSP. When temperature reaches timer start temperature, the timer
starts to count. After timer started counting, it will continue even if the
temperature drops below this start temperature. The timer can be reset to start
from beginning again. To reset the timer, press the knob momentarily, the display
will show rSt on top and "n" at the bottom, rotate the dial clockwise will change
the bottom display to "y". Press the knob again will reset the timer (Figure 4)
After the timer starts, the top display will be switched between the current
temperature and current time alternately in every 6 seconds. The temperature
and time display can be easily differentiated with their appearance. The
temperature reading has two or three digits. For example, 212 degrees will be
displayed as "212". The timer display has four digits with flashing colon in the
middle. For example, "01:20" for 1 hour 20 minutes.
When time counting ends, the controller will generate six long beeps. The top
display will switch between the current temperature and "End" alternately. After
timer ends, the power output can be configured either to continue heating, or
shut off. It is controlled by the parameter called ending options, EO. Set it to
ON for continue heating, set it to OFF to turn off the output.
If you want to use the timer as a regular timer without correlating to the
temperature setting, you can set the tSP below the ambient temperature (or
zero). The timer will start as soon as the regulator is powered up. You can use
the reset button (rSt) to reset the timer at any time.
Note 8. Alarm Function (for built-in buzzer only): ALH
DSPR400 has a built-in buzzer that can be programmed to beep when
temperature reaches the alarm set temperature, ALH. The alarm will generate
four short beeps every time the temperature rise from below ALH to higher than
ALH. The alarm function can be used to notify the operator when temperature is
approach the boil. The alarm function does not affect the heating or the time
function, it only provides the alarm sound.
Note 9. Temperature Control Tuning Parameters: oScr, AttE
The mashing control mode utilizes AI algorithm instead of the commonly used
PID or On/off control algorithm. The program is optimized for beer mashing. For
most system, there is no need to tune. It allows the system to heat up at
maximum speed, then hold the temperature stable with one-degree precision. If
you are not satisfied with the control result, these two parameters will help you
to fine tune the system. The overshot correction, oScr is for adjusting the
temperature overshot during the initial heat up. For example, if the temperature
overshot 3 degrees, set oScr = 3 should remove the overshoot. This parameter
has no effect after the temperature reach the set point. The attenuation
constant, AttE is for adjusting the temperature stability during mashing. The
value is from -2 to +2. The default value is 0. If the temperature fluctuates more
WWW.AUBERINS.COM
Initial
Setting Range
Remark
Setting
00:00~99:99
1:00
(hour: minute)
Note 7
-999~+9999 ° C
151
or ° F
-999~+9999 ° C
150
Note 8
or ° F
ON, OFF
OFF
Note 7
-100~+100
0
Note 9
-2~+2
0
P4/9