Auber Instruments EZboil DSPR120 Kullanım Kılavuzu - Sayfa 6
Kontrolör Auber Instruments EZboil DSPR120 için çevrimiçi göz atın veya pdf Kullanım Kılavuzu indirin. Auber Instruments EZboil DSPR120 10 sayfaları. Power regulator for boiling process automation
AUBER INSTRUMENTS
Note 10. Alarm Function: bALH
EZboil has a built-in buzzer that can be programmed to beep when temperature
reaches the alarm set temperature, bALH. The alarm will generate four short
beeps every time the temperature rise from below ALH to higher than ALH. The
alarm function can be used to notify the operator when temperature is
approaching the boil. The alarm function does not affect the heating or the time
function, it only provides the alarm sound.
7. Application examples:
1. Timer operation example:
The timer can be used for several ways to help the boiling process.
1) Use it to automatically control the boiling time (boiling mode).
Set the parameter as following
tF=on, btSP=210, tdIr=dn, bEO=OFF, bt=1:30,
The timer will start to count when temperature reaches 210 degrees. The timer
will count down from 1:30, when time out, the controller will stop heating, beeps,
and flash "End".
2) Use the timer as a regular timer (boiling mode).
Set btSP below the ambient temperature so that timer is available, set bt to a
very long time so that it will not end before operator decide to end the boil. The
counting direction should be up. Use the reset button (rSt) to reset the timer at
any time
tF=on, btSP=50, tdIr=up, bEO=on, bt=60:00.
3) Use the timer as a regular timer (mashing mode).
Set tSP below the ambient temperature so that timer is available, set t to a very
long time so that it will not end before operator decide to end the mash. The
counting direction should be up. Use the reset button (rSt) to reset the timer at
any time
tF=on, tSP=50, tdIr=up, EO=on, t=60:00.
4) Use EZboil as a manual regulator (similar to DSPR1)
To use it as manual regulator with temperature reading, please set it to boiling
mode. Disable timer, and set boiling acceleration set temperature below ambient
temperature (or just zero).
Mode=boiling, tF=off, bAST=0
8. Wiring Examples
Example 1. Here are two wiring diagrams of how to connect a DC triggered AC
SSR with this power regulator.
-
1
13
14
6
2
7
+
3
8
R
4
9
RTD
R
5
10
W
1
13
14
6
2
7
+
3
8
R
4
9
RTD
R
5
10
W
Figure 9. Wiring examples of controlling a heater with SSR and DSPR120 in a
120VAC system (upper) and in a 240VAC system (lower).
2017.03
4
3
SSR
Heater
4
3
-
SSR
Heater
9. Common sensor errors:
This regulator will display error message or incorrect temperature reading if your
sensor is not connected, or your sensor is bad. Top display will flash "orAL" and
"932" alternately, if you set it to Fahrenheit display (C-F =
alternately, if you set it to Celsius display (C-F =
N
120V AC
L
L1
240V AC
L2
Email: [email protected] Tel: 770-569-8420
Copyright 2007-2017, Auber Instruments All Rights Reserved.
No part of this manual shall be copied, reproduced, or transmitted in any way
without the prior, written consent of Auber Instruments. Auber Instruments
retains the exclusive rights to all information included in this document.
WWW.AUBERINS.COM
C).
°
Auber Instruments
5755 North Point Parkway, Suite 99
Alpharetta, GA 30022
www.auberins.com
F); or "orAL" and "500"
°
P6/9