Dametric CMD-DM2 Manuel - Sayfa 5
Kontrol Ünitesi Dametric CMD-DM2 için çevrimiçi göz atın veya pdf Manuel indirin. Dametric CMD-DM2 5 sayfaları.
Dametric AB
6
Installation
The DCM-DM2 is normally installed into
a step motor drive unit, CMU-2X. If the
unit is used alone then follow the
installation description below.
All electrical connections uses the J1
detachable plinth.
Peel of the insulation
app. 10 mm from the
wire end.
Use a small screw driver to unload the
spring connector and then insert the wire.
6.1
Power supply
1
+24VDC
3
0VDC
6.2
Step motor cable
5
SM-WA1
7
SM-WA2
9
SM-WB1
11
SM-WB2
6.3
Control I/O
13
DI-CLOSE
14
DI-OPEN
15
DI-HISPEED Move at high speed
15
DO-ALARM
7
Contact
Sales, development, production and service:
Dametric AB
Jägerhorns Väg 19, 141 75 Kungens Kurva, Sweden
Phone: +46-8 556 477 00
e-mail:
CMD-DM2 Manual EN.docx
Power supply to the module
Power ground
To control motor winding
To control motor winding
To control motor winding
To control motor winding
Close plates
Open plates
Alarm output
Web site:
CMD-DM2
CMD-DM2
J1
CMD-DM2
J3/5
J3/7
J3/9
J3/11
GND
J3/12
www.dametric.se
Nov. 21, 2019
1
19
2
20
A+
A+
A-
B+
B+
B-
GND
K-CM25K
dametric
Manual
CM-2NM...
1
A-
Step
2
motor
3
B-
4
GND
Page 5 of 5