4.2 Electrical Wiring

The electrical wiring must be performed by a
specialised electrician fully respecting current
standards and legislation in force. Check that the
power
supply
corresponds
requested by the hood, which is given on the silver
label stuck inside the hood. Ensure that the wiring
system conforms to current standards and the earth
discharge works efficiently. Pay special attention to
the hood power cable, ensure that it does not pass
through any holes without a cable clamp. For direct
connection to the electrical mains it is necessary to
provide a device that ensures disconnection from
the electrical mains, with an opening distance of the
contacts that allows the complete disconnection

4.2.1 Electrical Wiring Diagram

To control
buttons on hood
to
the
voltage
under the conditions of overvoltage category III, in
accordance with the rules of installation. The plug or
Omni polar switch must be accessible when the unit
is installed.
If the power cord is damaged, it must be replaced by
a special cord or assembly available from the
manufacturer or its service agent. The cable must be
of type H05VV-F 3 x 0.75mm
section.
The manufacturer declines all responsibility if the
current accident prevention standards in force are
not respected, which are needed for the wiring
system to operate correctly.
To motor
plug
To light
transformer
Supply
2
minimum cross-
7