5.3 Weighing procedures

5.3.1
Press [ON/OFF] to turn on the balance.
When power is turned on, all display segments appear on LCD for a few seconds and finally
"0" will appear on the display.
5.3.2

Changing Units

Press [UNIT] to select a weighing unit, eg. "g"、" ct " 、" oz "、" tola " .......
Once the unit has been selected, the selected unit will be displayed to the weight value.
5.3.3

Start weighing

If you do not use a container for weighing
Verify the reading is "0". If not, press [ZERO] to display "0".
Place objects on the weighing platform to weigh.
When the reading becomes stable, the stable indicator is displayed.
If you use a container for weighing
Place an empty container on the platform.
Wait for the stability indicator to be displayed and press [ZERO].
Place the objects to be weighed in the container.
When the reading becomes stable, the stable indicator is displayed.

6. FUNCTION SETTINGS

Press [ON/OFF] to turn on the scale, the display will show flash digits and then --------,

6.1 Setting BAU Value

Press [PRINT], the display will show b xxx BAU value (press [UNIT] to select among 1200,
2400, 4800, 9600), our default setting is 9600.

6.2 Setting Parity Mode

Press [ZERO] to enter Parity mode, the display will show P xxx PAR, press [UNIT] to select
odd, even, none (odd stands for 7 data bits with odd parity, even stands for 7 data bits with
even parity, none stands for 8 data bit without parity)our default setting is none.

6.3 Setting Print Mode

Press [ZERO] to enter Print mode, the display will show n xxx, press [UNIT] to select CON,
OFF, KEY, STB (CON stands for continuous print, OFF stands for serial data output
disabled, KEY stands for demand mode by press [PRINT], STB stands for automatic print
when scale is stable, our default setting is STB. Press [ZERO] again to return to weighing
mode.

6.4 Setting Unit Selection

Press [UNIT] to enter unit selecting function, the display will show ON X (X stands for the
units: g,oz, lb,twt...tola..), press [UNIT] to select ON (activate the selected unit) or OFF
( inactivate the selected unit), press [ZERO] again to return to weighing mode.

6.5 Setting ZERO track

Press [TARE] key to enter ZERO track function setting, display shows ZRD x.x,press [UNIT]
key to select ZERO track value(0.0d-0.5d-1.0d-1.5d-2.0d), press [TARE] key to enter
5 |