3.3.1. Sample number alarm:
Lack of Sample light will turn on if the total weight of sample is below the limit value, by
adding the sample piece with counting until the lack of sample light is turned off.
Then set the new numbers of sample through numeric key then press [SAMPLE/UNIT] key.
FREE SAMPLE FUNCTION is the same as the above; scale will automatically adjust and
calculate new average unit weight if operator add samples in slowly with the numbers.
FREE SAMPLE FUNCTION will not work if the displayed number exceeds 1,000,000
pieces.
3.3.2 Unit weight alarm:
Lack of Piece Weight light will turn on if the averaged unit weight or set unit weight is not
enough for accurate counting operation. Operator may use scale even the light is on, but
counting error might occur.
3.3.3. Alarming by press [QTY/SET]:
THE SCALE has useful check function to inform operator that the total piece counts
quantity has reached the lower limit and the upper limit desired. This function is designed
for packing purpose. For example, if the operator wishes to count 1,000 pieces for every
package, he can set the lower limit and the upper limit as 1,000 pieces as following:
(1) Press [QTY/SET] enter quantity alarm menu.
(2) Setting quantity alarm: repeat step (1), enter quantity alarm menu, press [ZERO] key
to select, select "CH=on", this means quantity alarm is turned on. If "CH=off" is
selected, this means quantity alarm is turned off.
(3) Setting lower limit and upper limit: repeat step (1), enter quantity alarm menu, press
[TARE] key to select. when the display shows "L=0000"(L for flash), press digital key,
input "990" then press [TARE] key again, input lower limit is complete. The display will
show "H=0000"(H is flashing), press digital key, input "1010" then press [TARE] key
again, input upper limit is complete.
(4) Exit the quantity alarm menu: press [QTY/SET] key to exit the quantity alarm menu.

4. Function setting

4.1 Turn off the scale.
4.2 Press and hold [UNIT WEIGHT] key to turn on the scale, the display will show.
And then b=ON/OFF on the first line, A-XX on the second line and L=ON/OFF on the
third line.
Press [QTY/SET] to select activate or inactivate the function of the beep.
Press [TARE] to select auto off time. Press [ZERO] key to select activate or inactivate
the function of the backlight.
4.3 UNIT WEIGHT function: when there is no weight on the platform, press [SAMPLE/UNIT]
key to select the unit (kg or lb). When there is something on the platform, press [UNIT
WEIGHT] key to sample.