Anyload OCSM Series Kullanıcı Kılavuzu - Sayfa 10
Terazi Anyload OCSM Series için çevrimiçi göz atın veya pdf Kullanıcı Kılavuzu indirin. Anyload OCSM Series 16 sayfaları. Light duty crane scale
Resolution Switch
o
Press
o
o
o
o
o
For information about Resolution, refer to User Setup.
Battery Power View
o
Press
o
Scale displays battery voltage, for example
6.38V.
For information about battery, refer to Battery Maintenance
7.
User Setup
o
Press
o
Message
o
Press
9 |
ANYLOAD OCSM Series Light Duty Crane Scale User's Guide
, and then press
Scale displays new resolution.
High resolution offers better accuracy at the cost of longer
measuring time and stricter requirement of load's stability.
Designed to meet the OIML R76's directive, the scale has the
best (default) performance at 2000 to 3000 division.
Resolution Switch changes the apparent overloading range of
scale. For example, if a 3000*1kg scale is switched to
3000*0.5kg, it will overload at 3004.5kg (3000 + 9*0.5), while
by default, it overloads at 3009kg (3000 + 9*1).
Default resolution will be restored next time when scale is
powered on or enter User Setup. To save changes in
resolution for later, enter User Setup and change Resolution.
, and then press
, and then press
displays.
will enter Resolution.
, switch display resolution
to view battery power.
, enter User Setup mode.
, indicating