USER RESPONSIBILITY

This equipment will perform in conformity with the description contained in
this manual and accompanying labels and/or inserts when installed, operated,
main tained, and repaired in accordance with the instructions provided. This
equip ment must be checked periodically. Improperly working equipment
should not be used. Parts that are broken, missing, worn, distorted or
con tam i nat ed, should be replaced im me di ate ly. CONCOA recommends
that a tele phone or written request for service advice be made to CONCOA
Cus tom er Service in Virginia Beach, Virginia, PHONE: 1-800-225-0473,
FAX: 1-757-422-3125, or E-MAIL: [email protected].
This equipment or any of its parts should not be altered without prior written
ap prov al by CONCOA. The user of this equipment shall have the sole
re spon si bil i ty for any malfunction that results from improper use, faulty
main te nance, damage, im prop er repair, or alteration by anyone other than
CONCOA or a ser vice facility des ig nat ed by CONCOA.
SAFETY
Specifi c procedures for the safe use of regulators are listed below. The
user can form habits that will prevent an accident due to confusion over
chang ing service needs. Refer to CONCOA publications ADE 872, latest
revision, Safe Practices in Welding and Cutting.
a. Never subject the regulator to inlet pressure greater than its rated inlet
pressure, as shown on regulator body.
b. Never use the regulator for gases other than those for which it is intended.
c.
Check the cylinder valve outlet before attaching a regulator to a cyl in der.
Do not use the cylinder if oil, greas, or dirt is present
Do not allow oil, grease, or other combustibles to contaminate
ox y gen equipment or areas where oxygen is in use. Do not place
a con tam i nat ed regulator into service.
The regulator relief valve only protects the regulator. Downstream
equipment may require additional pressure relief devices.
d. To minimize heat effects, avoid use of piping or tubing between cyl in der
and oxygen regulator. If unavoidable, it should be as short as practicable
and equipped with a shutoff valve located just before the regulator. Keep
the shutoff valve closed when pressurizing. If reg u la tor is connected to a
manifold, open the valve of the cylinder closest to the regulator fi rst, then open
the remaining cylinder valves. In either case, when the fl ow to the shutoff
valve stops, wait 60 seconds and then slowly open the shutoff valve. DRAIN
OXYGEN REG U LA TOR OF GAS BEFORE PRESSURIZING.