MONITOR (loop out of RF_OUT)
Connector:
Impedance:
Rated Power:
Note: It is OK to leave this port open without load.
RS232-A
Connector:
Note:
RS232-B:
Connector:
Note:
RJ45
Connector:
Note:
FWD
Connector:
Input Level:
Note:
REF
Connector:
Input Level:
Note:
Note:
1)
The back fan covers can also be removed to clean the air intake path. No screw driver is needed, and
no disassembly of the PA is required.
ACT-560PA-USR-DOC-V1.1, 09/15/2014
BNC female
50 Ω
0 dBm ± 3 dB @ 700 W
DB9-M
Connected to REMOTE (RS232) port of ACT-5X, which is used
for control and communication between the PA and the exciter.
DB9-M
Reserved
10M/100M Ethernet
For customers' remote control to the PA.
SMA
-20 to +10 dBm
External Coupler Forward sample for PA_FWD Power Meter.
SMA
-20 to +10 dBm
External Coupler Reflected sample for PA_REF Power Meter.
PA-560W User Manual