Always disconnect the appliance from the
electricity main before making any adjustments.
All seals must be replaced by the technician at
the end of any adjustments or regulations.
Our burners do not require primary air
adjustment.
9) TAPS
"Reduced rate" adjustment
Switch on the burner and turn the relative knob to
the "Reduced rate" position (small flame fig. 1).
- Remove knob "M" (fig. 13 and 13/A) of the tap,
which is simply pressed on to its rod. The by-pass
for minimal rate regulation can be: beside the tap
(fig. 13) or inside the shaft. In any case, to access
to regulation, it can be done trought the insertion of
a small screwdriver ''D'' beside the tap (fig. 13) or in
the hole ''C'' inside the shaft of the tap
(fig 13/A). Turn the throttle screw to the right or left
until the burner flame has been adequately
regulated to the "Reduced rate" position.
The flame should not be too low: the lowest small
flame should be continuous and steady. Re-assemble
the several components.
ADJUSTMENTS
TAPS LUBRIFICATION
Should a tap being blocked, do not
force and ask for Technical
FIG. 13
It is understood that only burners operating with
Natural should be subjected to the above
mentioned adjustments. The screw must be fully
locked when the burners operate with Liquid
Petroleum (LPG) gas.
WARNING:
To adjust the minimum "DUAL" burner first
remove the bushing "E" (fig. 13).
In the case of a "DUAL" burner, the
regulation screw situated inside the post of
the valve regulates the central flame, while
the screw next to the valve regulates the
outer flame.
Assistance.
12