Duerkopp Adler 506 Kurulum Talimatları Kılavuzu - Sayfa 5
Dikiş Makinesi Duerkopp Adler 506 için çevrimiçi göz atın veya pdf Kurulum Talimatları Kılavuzu indirin. Duerkopp Adler 506 8 sayfaları.
Ayrıca Duerkopp Adler 506 için: Kullanım Talimatları Kılavuzu (17 sayfalar)
3.2 Checking the Nominal Voltage
3.3 Setting the Motor Protection Switch
6
The nominal voltage listed on the rating plate of the sewing drive and
the mains voltage must agree !
For conversion to a different mains voltage the appropriate voltage kit
must be mounted.
The voltage kit consists of:
V-belt pulley, V-belt, protection switch insert
Nominal voltage:
3 ~ 380 - 415 V + N, 50 Hz
3 ~ 220 - 240 V, 50 Hz
3 ~ 220 - 240 V, 60 Hz
"Delta"
When converting to a different mains voltage the wiring must be
changed. The wiring is shown in the components connection schematic.
The bridges in the motor terminal box are to be switched in "Star" or
"Delta" according to the mains voltage .
The motor protection switch 1 must be set according to the mains
voltage.
220 - 240 V:
380 - 415 V:
Order no.:
9880 506001
9880 506002
9880 506003
"Star"
2.5 - 4 A
4 - 6.3 A
1