4.

Electrical connection

5
6
1
2
3
4
CAUTION:
The mains voltage must coincide with the rated voltage specified on
the name plate.
The machine adapts the local mains voltage via connection terminals 1
to 5 and A to D of the transformers in the control box.
Both the transformer terminals are factory-set to a mains voltage of
230 V.
For different mains voltages the terminals must be connected as
follows:
Strip terminal 2:
Voltage
blue
200V
A
230V
A
240V
A
On strip terminal 5 the brown-and-white and blue-and-white wire
jumpers must be changed. Both connection terminals are given in the
table.
Example:
"L-4" means place the wire jumper between terminals L and 4.
Strip terminal 5:
Voltage
brown-and-white blue-and-white
190V
L - 4
200V
L - 4
210V
L - 4
220V
L - 5
230V
L - 5
240V
L - 5
Undo screws 3.
Carefully remove the cover 4.
Check the configuration of the connections to the transformer
plug strips.
If necessary change the connections in line with the mains
voltage.
Re-attach the cover 4 with screws 3.
brown-and-white
B
C
D
N - 3
N - 2
N - 1
N - 3
N - 2
N - 1