Duevi DIRRV2 868 Kurulum ve Kullanım Kılavuzu - Sayfa 4
Güvenlik Sensörleri Duevi DIRRV2 868 için çevrimiçi göz atın veya pdf Kurulum ve Kullanım Kılavuzu indirin. Duevi DIRRV2 868 4 sayfaları. Infrared wireless detector
DIP3 = OFF
J.TMP = CLOSED
J.APPR = CLOSED
4. Press the tamper switch TMP.CO
5. Verify the control panel learnt the detector radio code, then save the learning on panel
6. Set the detector into normal operation mode:
J.APPR = OPEN
6. SUPERVISION
Supervision is always active on the detector. The detector supervision can be managed in the control panel settings (SETUP> DEVICES).
7. SENSOR CALIBRATION
Unplug the battery from detector
Set DIP4 = ON (LED ON) and DIP1 = OFF (TEST mode)
Plug the battery, wait some minutes (detector stabilization) and close the cover
Perform some tests of the detector (detection and radio range) placing it in the installation point.
After each sensitivity adjustment (acting on trimmer) wait some seconds the detector stabilization:
•
turn trimmer clockwise to increase sensitivity
•
turn trimmer counter clockwise to decrease the sensitivity
When "pulse count" is set to 2 (DIP2 = ON) the sensitivity is lower.
Once finished adjustments, the detector MUST be set in NORMAL working mode (DIP1 = ON)
If necessary, change the installation point and detector orientation.
8. NORMAL WORKING
Set DIP4 = OFF (LED OFF) and DIP1 = ON (NORMAL mode) to have battery low absorption.
Fix the detector in the position identified by testing phase and close the cover.
When in NORMAL mode, the detector sends alarm only after three minutes of complete absence of movement.
The detector has max detection sensitivity when its detection area is crossed in a transversal way (perpendicular to the sensor).
(anti-opening tamper enabled)
(anti-removal tamper disabled)
(detector in "learning" mode)
THIS DEVICE MEETS THE R&TTE REQUIREMENTS (EUROPEAN UNION)
MADE IN ITALY