AirVax 33X2 Kullanıcı Kılavuzu - Sayfa 4

Hava Temizleyici AirVax 33X2 için çevrimiçi göz atın veya pdf Kullanıcı Kılavuzu indirin. AirVax 33X2 16 sayfaları. Permanence-static electricity-film-filter air purifier
Ayrıca AirVax 33X2 için: Kullanıcı Kılavuzu (8 sayfalar)

AirVax 33X2 Kullanıcı Kılavuzu
LIMITATIONS ON THE USE OF THE REMOTE CONTROL
DO NOT USE THE REMOTE CONTROL IN THE FOLLOWING LOCATIONS:
Any location where inverter lighting equipment or electronic spontaneous lighting equipment are installed
The remote control may become inoperable. In this case, move away from such lighting equipment or change locations.
Location exposed to direct sunlight
The unit may not receive signals from the remote control.
The unit may not respond to the signals of the remote control if the ends of the fluorescent lighting turn black or lights flicker
due to the expiration of the service life; note, however, that this is not a malfunction of the remote control or the main unit. In
this case, replace the lighting with new fluorescent tubes.

INSTALLATION GUIDELINES

Allow a distance of at least 7 feet (2m) from equipment generating electric waves such as televisions, radios,
or wave clocks (to avoid electric interference).
Avoid locations where curtains, etc., may come into contact with the intake or air outlet
(curtains, etc., may get dirty, or malfunction may occur).
Do not move the product by holding it by the top cover.
The top cover is used to open/close the equipment
(if the cover is not completely closed, the equipment may fall and mechanical failure may occur).
EFFECTIVE OPERATION
Place on a stable surface with sufficient air circulation

FILTER GUIDELINES

Do not smell the filter by putting your nose close to it. Avoid skin contact with the equipment.
Do not wash a contaminated filter. Instead, remove the dust using a vacuum cleaner or a brush.
Dust may accumulate on the unit even when it is not operating.
Therefore, cover the unit with any vinyl material when the product will not be used for a long time.

CARE AND MAINTENANCE

1. FILTER CLEANING
Take note of the pollution level on
Turn off power and unplug the
Open the cover by turning the top
Viewfinder on the reverse side.
cord from the wall outlet.
cover toward the "OPEN" direction.
Schedule of Filter Change
The SEFF
after simple, quick cleaning even when the gap is filled with dust and
the unit does not take in as much dust as the new filter. When used
for a long time, however, the filter may be severely discolored.
Turn the top cover to the opposite
Place the unit on the ground, plug
Therefore, change the filter at least once every three years. For more
detailed information, contact the head office.
direction of "OPEN."
the cord, and turn on power again.
2. MAIN UNIT
To prevent dirt or stains on the main unit, clean as often as necessary (stains may be difficult to remove later if they are not
cleaned immediately).
Wipe with a soft, dry cloth.
For stubborn stains or dirt, use a soft cloth soaked in warm water (squeeze off excess water).
Do not use volatile fluids on the unit
(benzene, paint thinner, polishing powder, etc., may damage the surface of the
unit).
Do not use detergents in cleaning the unit
(detergent ingredients may damage the surface of the unit).
Keep the unit dry.
Keep unit away from moisture.
6
Use a brush or a vacuum cleaner to
remove dust from the upper filter.
(Static Electricity Film Filter) of AIRVAX can be reused
TM
OPERATION
1. OPERATING THE MAIN UNIT
Button Click
Mode
Contents
(ON)
The unit will operate at MEDIUM fan level
Once
Normal mode
The two lights at the bottom of the LED will be turned on.
The unit will operate at HIGH fan leve
Twice
High mode
The three lights on the LED will be turned on.
The unit will operate quietly using minimal air intake.
Three times
Silent mode
The light on top of the LED will be turned on.
Power is turned off.
Four times
OFF
Both lights are turned off.
2. OPERATING THE REMOTE CONTROL
When you start the remote control, the LED will blink rapidly and shift to the appropriate mode.
ON/OFF
The First click will turn on power; the second click will turn off power.
High mode
The unit will operate at HIGH fan leve.
Normal mode
The unit will operate quietly using minimal air intake.
Silent mode
The unit will operate quietly using minimal air intake.

SPECIFICATIONS

Model
Power supply
Input :AC 100~240V / 50~60Hz Output : DC 12V / 1.0A
Fan level adjustment
High mode
Fan level
Rated power
2W
operation
Fan level CFM(m
3
/min.)
80(1.4)
Applicable floor surface
Cord length
6-15/16 in. 6-15/16 in. 11-1/2 in
Dimensions(W D H)
Weight
* The applicable floor surface area is appropriate for operating the unit at maximum fan level.
Display
AIRVAX-33X2
Normal mode
Silent mode
1W
0.5W
62(0.8)
41(0.5)
269 sq.ft.* (25m
)
2
5.9ft (1.8m)
177mm 177mm 292mm
3.7 lbs (1.7kg)
7