Duke HDC-37.5-240 Servis Kılavuzu - Sayfa 15
Mutfak Aletleri Duke HDC-37.5-240 için çevrimiçi göz atın veya pdf Servis Kılavuzu indirin. Duke HDC-37.5-240 20 sayfaları. Foodservice equipment
SYMPTOM
Heating Elements do not
heat.
One Heating Element does
not heat.
Heating Elements
operating but no indication
on the Display Box.
TROUBLESHOOTING
CAUSE
Unit not plugged in
Main Power On/Off Switch not in on position
Faulty Control Board
Defective Heating Element or Hi-Limit Thermostat
Defective RTD
Defective SSR
Defective Control Board
Defective Display Board
Service Manual for Dry Channel HDC3/HDC6 Units
Plug unit in to proper power outlet.
Move the Main Power On/Off Switch to on position.
Replace Control Board.
Check resistance across Heating Element and
Hi-Limit Thermostat. It should be around 124Ω.
Replace Channel Assembly if test fails.
Check resistance across RTD at ambient room
temperature. Resistance should be approximately
1000Ω. Replace Channel Assembly if test fails.
Replace SSR.
Replace Control Board.
Replace the Display Board.
REMEDY
15