Vibrations.
The appliance
seems to make too
much noise.
The door will not
close properly.
Display "E0", "E1".
"E2", "E3", "E4",
"E5", "E6" or "E7".
The alarm sounds
and the
temperature
display flashes.
The icon "--" is lit
up and flashing in
the temperature
display.

WARRANTY

The warranty does not cover:
1.
Damage in transit or when moving the appliance.
2.
Any damages caused from negligence, accident, improper use, improper installation/service or
use for purposes other than those described in the instruction manual.
3.
Damage caused by connecting your product to the wrong power source.
4.
Damage from power failure.
5.
Faulty installation or modification made during installation.
6.
Damage caused by unauthorized repair.
7.
Any damages resulting from force majeure, fire disaster or natural disaster.
8.
Alterations to the product without express permission from the manufacturer.
9.
Parts such as light, removable shelves, or plastic.
10. Any spoilage or damage to wines or any other contents incidental or consequential to possible
defects of the unit.
NOTE: The warranty clauses and specifications are subject to change without notice.
The appliance is not properly level.
The rattling noise may come from the flow of the refrigerant, which is normal. As each
cycle ends, you may hear gurgling sounds caused by the flow of refrigerant in your
appliance.If temperature fluctuations occur, the contraction and expansion of the inner
walls may cause popping and cracking noises.
The appliance is not properly level.
The appliance is not properly level.
The door was reversed and not properly
installed.
The gasket is dirty.
The shelves are out of position.
"E0" indicates the communication error for 3
zone models.
"E1" or "E2" indicates that the air
temperature sensor is failed.
"E3" or "E4" indicates that the defrost sensor
in the evaporator is failed.
"E5" indicates the defrost heater failure.
"E6" indicates the solenoid valve failure.
"E7" indicates the door switch failure.
Has the appliance door been open for longer
than 60 seconds? If not, then the
temperature has risen higher or fallen lower
than the temperature that has been set. This
could be due to:
The appliance door being opened too often.
The ventilation opening being covered or too
dusty.
A lengthy interruption to the power supply.
A large amount of bottles has been added to
the unit.
The display temperature is out of the range.
15
Level the appliance with the
adjustable feet.
Level the appliance with the
adjustable feet.
Level the appliance with the
adjustable feet.
Check the door hinge and
reassemble correctly.
Clean the door gasket.
Check the shelves and refit
correctly.
Call for service.
If yes, close the door.
Do not open the door more often
than necessary.
Clear the obstructions and clean
the dust.
Leave the appliance to work for a
while until the set temperature
has been reached.
Only temperatures within the
range 0~99°F/-9~37°C the
appliance can display will be
shown. If the temperature is not
within this range, the icon "--" will
be displayed instead. That is