CashCode SNR Yazılım Açıklaması - Sayfa 2

Endüstriyel Ekipmanlar CashCode SNR için çevrimiçi göz atın veya pdf Yazılım Açıklaması indirin. CashCode SNR 2 sayfaları. Bill recycler, currency: 50, 100, 500, 1000, 2000, 5000 venezuelan bolivar fuerte vef

EXTERNAL COMMUNICATION INTERFACE FEATURES:
MDB INTERFACE
Country Code = 1937h
Decimal Place = 0
Scaling Factor = 50
MDB Level: 1(sw2.3=OFF) or 2 (sw2.3=ON)
DIP SWITCHES SETTING:
Switch 1
ON state
SW1.1
50 VEF Disabled
SW1.2
100 VEF Disabled
SW1.3
500 VEF Disabled
SW1.4
1000 VEF Disabled
SW1.5
2000 VEF Disabled
SW1.6
5000 VEF Disabled
SW1.7
Reserved
SW1.8
Reserved
Switch 2
ON state
SW2.1
High Security
SW2.2
Override rules disabled
SW2.3
MDB v.4.0 Recycler
SW2.4
Service Mode
RECYCLING CASSETTE CONTROLS:
The Recycling Cassette controls are shown on the drawing below.
/ & ' G L V S O D \
Default
OFF state
Setting
50 VEF Enabled
OFF
100 VEF Enabled
OFF
500 VEF Enabled
OFF
1000 VEF Enabled
OFF
2000 VEF Enabled
OFF
5000 VEF Enabled
OFF
Reserved
OFF
Reserved
OFF
Default
OFF state
Setting
High Acceptance
OFF
Override rules enabled
OFF
Universal recycler
OFF
To work with a "Host
OFF
Machine Controller"
) H H G E X W W R Q
8 Q O R D G E X W W R Q
' , 3 6 Z L W F K H V
RECYCLING CASSETTE DIP SWITCHES SETTING:
Switch
ON state
SW1
Assign for 1000 VEF
SW2
Cassette setup mode
RECYCLING CASSETTE INDICATOR
After power on Recycling cassette indicator shows control firmware version:
F1 -> 24
After initialization indicator shows number of bills inside of the recycling
cassette.
In case of an error it will start flashing showing consequently number of bills
and one of the following error codes:
E0h
– there was a hardware error detected
E1h
– no communication with Coin Changer. In this case device will emulate
Coin Changer with 1 tube (5000 VEF or 10000 VEF).
FEED/UNLOAD BUTTONS
The Feed button is used for setting a Loading mode. This mode makes the
entered bills of a selected denomination to be loaded into the recycling
cassette. To cancel a loading mode, the Feed button must be pressed again.
If bills do not enter within 20 second s, the loading mode will be canceled
automatically.
By pressing the unload button one bill will be dispensed from the recycling
cassette through the entry channel. If the feed and unload buttons are pressed
simultaneously then all bills will be unloaded from the recycling cassette into
the drop cassette.
RECYCLING CASSETTE SETUP MODE
Recycling Cassette setup mode allows user to adjust recycling cassette feed
and unload levels (maximal number of bills accepted into the cassette and
number of bills to be left in the cassette during unload operation
correspondingly) without need of special equipment. In order to enter the setup
mode set SW2 to ON. The cassette indicator will start blinking "FL"(Fill level)
or "UL"(unload level) and the set level consequently. Press FEED button to
increase level and UNLOAD to decrease it. In order to switch between feed
and unload settings press two buttons simultaneously.
When setting is done set SW2 to OFF. Unit will switch to normal operation. No
power cycling is necessary.
Default
OFF state
Setting
Assign for 500 VEF
OFF
Normal operation
OFF