CashConcepts CCE 415 P Manuel - Sayfa 17

Para Sayma Makineleri & Bozuk Para Ayırıcılar CashConcepts CCE 415 P için çevrimiçi göz atın veya pdf Manuel indirin. CashConcepts CCE 415 P 18 sayfaları.

CCE - Cash Concepts Europe GmbH
Kemptener Straße 99 – D-88131 Lindau / Germany
Tel.: +49 (0)8382 – 943 15 – 0 / Fax: +49 (0)8382 – 943 15 – 20
Email: [email protected] / Web: www.cce.gmbh
Error Message
Error Message
IR sensor error
Metal sensor error
Rotate speed sensor error
Please remove the gasket
Please replace the brush
Coins were not transported or jammed
Replacing the fuse
The CCE 415 is protected by a fuse which can be exchanged by you without big expenditure in case of need.
Please switch off the machine before the change of the fuse and pull the net plug from the device. There is mortal danger on
the basis of electric shocks by no observance.
Draw off the cover of the fuse and exchange it with an equivalent one. The fastener of the fuse must be pressed after the change
again firmly.
Troubleshooting
Please clean the sensors of the machine, as described in the
corresponding chapter of this manual.
Please contact your service partner, the machine must be
repaired by a technician.
Please refer to the chapter Fault Management and Maintenance
in this manual, there are instructions for removing this message.
The Transport brush is worn and must be replaced, please
contact your service partner or CashConcepts Europe GmbH.
Remove the safety pin and increase the pressure of the transport
brush spin direction. "-" And fasten the brush then again with the
safety pin