Danfoss HP75A-1 Talimatlar - Sayfa 2

Termostat Danfoss HP75A-1 için çevrimiçi göz atın veya pdf Talimatlar indirin. Danfoss HP75A-1 4 sayfaları. Electronic programmable heat pump thermostats with integral/remote sensor

Setting record for thermostat set for
six events each day
Format
1
2
CLG
HTG
CLG
HTG
Pre-set programmes, Monday to Friday
25.0°C
20.0°C
27.2°C
15.0°C
25.0°C
6:30
8:30
Actual User Settings, Monday to Friday
1 (Monday)
2 (Tuesday)
3 (Wednesday)
4 (Thursday)
5 (Friday)
Pre-set Programmes, Saturday & Sunday
27.2°C
20.0°C
27.2°C
20.0°C
25.0°C
7:30
9:30
Actual User Settings, Saturday & Sunday
6 (Saturday)
7 (Sunday)
If the unit is to operate in 5/2 day mode, then only days 1 and 6 need be completed.
NOTES ON SETTING EVENT TIMES
(Assumes unit is in 6 events/day mode)
If, during the event checking and setting procedure, no buttons are
pressed for more than two minutes then the HP75 will return to RUN
mode automatically. If this appears to have occurred, it is advisable to
re-check the program to ensure that it is as required.
When setting event times and temperatures it is not possible to set
event times out of chronological order.
Event 1 may be set at any time from 0:00AM to 11:59PM (but would
normally be in the morning).
Event 2 may be set at any time between event 1 and 23 hours, 59
minutes after event 1.
Event 3 may be set at any time between event 2 and 23 hours, 59
minutes after event 1.
Event 4 may be set at any time between event 3 and 23 hours, 59
minutes after event 1,.... and so on.
32°C
31°C
30°C
29°C
28°C
COOLING
27°C
26°C
25°C
24°C
5°C
23°C
FACTORY
DEAD
22°C
PRE-SET
BAND
21°C
PROGRAMME
20°C
19°C
18°C
17°C
16°C
HEATING
15°C
14°C
13°C
MIDNIGHT
3:00
6:00
9:00
32°C
31°C
30°C
29°C
28°C
COOLING
27°C
26°C
25°C
24°C
23°C
EXAMPLE
3°C
22°C
USER SET
DEAD
21°C
BAND
PROGRAMME
20°C
Manual overide
19°C
MANUAL OVERRIDE = USED
18°C
to raise temperature by 2°C.
AT 9 AM TO RAISE
17°C
TEMPERATURE BY 2°C.
16°C
Programmed 3°C dead band
HEATING
PROGRAMMED 3°C DEAD
15°C
BAND MAINTAINED.
maintained.
14°C
13°C
MIDNIGHT
3:00
6:00
9:00
2
Event Numbers
3
4
5
CLG
HTG
CLG
HTG
CLG
HTG
CLG
20.0°C
27.2°C
15.0°C
25.0°C
20.0°C
27.2°C
11:30
13:30
16:30
20.0°C
25.0°C
20.0°C
25.0°C
21.1°C
27.2°C
11:30
13:30
16:30
12:00
15:00
18:00
21:00
used at 9am
12:00
15:00
18:00
21:00
Setting record for thermostat set for
6
Format
HTG
15.0°C
22:30
1 (Monday)
2 (Tuesday)
3 (Wednesday)
15.0°C
22:30
4 (Thursday)
5 (Friday)
6 (Saturday)
7 (Sunday)
If the event time being set is moved past midnight into the following day
then the number of the following day will blink.
00:30
12:30
When using the + button to adjust events 1 to 5 and the event time
being adjusted becomes the same as the following event time, then
both are changed simultaneously. This applies to all subsequent event
times reached and is demonstrated in the diagram on the lower left.
When using the - button to adjust events 2 to 6 and the previous event
time is reached the - button ceases to respond.
The factory pre-set programme may be reinstated by pressing the
recessed RESET button. This will however reinstate all the factory pre-
set conditions so that the clock type and temperature scale may also
have to be re-set.
MIDNIGHT
In the diagram opposite, event 2 has been moved to 3:30PM. Note that
events 3 & 4 have also been moved to that time and that the following
control temperature will be that of event 4.
It is possible to move events past midnight into the following day when
the day number will blink in the display, see the display diagram in the
notes on setting event times.
MIDNIGHT
two events each day
Event Number
1
2
CLG
HTG
CLG
HTG
Time
TIme
Pre-set programmes, Monday to Friday
25.0°C
21.1°C
Off
15.0°C
8:30
17:30
Actual User Settings, Monday to Friday
Pre-set Programmes, Saturday & Sunday
Off
Off
Off
Off
8:30
17:30
Actual User Settings, Saturday & Sunday
15.0°C
Event 6 on day 6 set after
midnight.
am