Ignition
Consideration needs to be given to the placement of the electronic ignition module. Avoid placing
the module in the path of hot air. Mount the ignition module using the four supplied rubber grommets
so as to create a 1/16" gap between the ignition module and the mounting surface. Without this
1/16" gap the ignition module can overheat. Important: If the electronic ignition overheats it will
malfunction (e.g., backfiring or shutting down).
Ignition details:
The red cable is positive (+)
The ignition timing has been set at our factory
When fitting a new ignition it is important to achieve the correct coordination of the sensor(s)
to the magnets
Canister mufflers
To prevent damage to the header(s) a flexible support bracket is required to mount the canister(s).
The location for this bracket should be at the canister's center of gravity. 3W canisters have a
reinforcement ring at this location.
We suggest creating two compartments in the front section of the fuselage by installing a horizontal
3W 170xi B2 / TS / CS Engine Manual
Refer to our special ignition description for further information