Danfoss D1P145 Kullanıcı Kılavuzu - Sayfa 10

Su Pompası Danfoss D1P145 için çevrimiçi göz atın veya pdf Kullanıcı Kılavuzu indirin. Danfoss D1P145 15 sayfaları. Axial piston pump, variable displacement

Danfoss D1P145 Kullanıcı Kılavuzu
User Manual
ATEX certified D1P 130/145/193/260

Installation, operation and maintenance

Assembly of D1 pump to the system

10 |
©
Danfoss | August 2021
When assembling the pump in the machine/system it is the builder's responsibility that the parts used
conform to the ATEX directive and that the components are assembled and running according to the
operational data/design found in product data sheets and instructions.
Only use the pump as required by the explosion protection shown on the name plate.
Always ensure that the following is maintained:
The supporting frame, chassis, or structure of equipment containing the pump shall be constructed
of electrically conducting material and shall be so arranged as to provide a leakage path to earth
(ground) for any static electricity which occurs on the pump.
It is compulsory to use oils whose inflammable degree is at least 50K above the maximum surface
temperature of the pump. Maximum surface temperature is 200° C for Group 11G.
Make sure that all type of accessory installed on the pump are ATEX specified and have been installed
in accordance with ATEX requirements.
There are no creeping metal elements external to the pump.
There are no plastic parts that might accumulate electrostatic; or they are shielded.
The maximum permissible oil and ambient temperature is monitored and not exceeded for the
category and temperature class of the associated zone.
Manufacture the assembly flange on the machine/system where the pump has to be installed: the
relevant surface has to be perfectly smooth, completely de-greased and non-deforming.
It is necessary to verify the perfect alignment between the pump input shaft and the counter part – the
fitment between pump shaft and application's driven shaft must be executed so that no radial or axial
pre-load is generated – these extra loads reduce the bearings expected lifetime.
BC376161003883en-000101